Determination of 5-methyltetrahydrofolic acid in human serum by stable-isotope dilution high-performance liquid chromatography-mass spectrometry

被引:41
作者
Pawlosky, RJ
Flanagan, VP
Pfeiffer, CM
机构
[1] USDA ARS, Beltsville Agr Res Ctr, Beltsville Human Nutr Res Ctr, Food Composit Lab, Beltsville, MD 20705 USA
[2] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Environm Hlth Lab Sci, Atlanta, GA 30333 USA
基金
美国国家卫生研究院;
关键词
5-methyltetrahydrofolic acid; folate; electrospray mass spectrometry; human serum; isotope dilution;
D O I
10.1006/abio.2001.5394
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The need for specific and sensitive methods for the determination of distinct serum folates is of high priority in clinical research settings. A stable-isotope liquid chromatography-mass spectrometry (LC/ESI-MS) assay was developed for the quantitative determination of the monoglutamyl form of 5-methyltetrahydrofolic acid (5-MTHFA) in human serum. Serum samples (0.5 ml) were amended with the internal standard, [5-C-13(5)]MTHFA that had been labeled on the glutamic acid portion of the molecule and allowed to equilibrate. The analyte was trapped onto a solid-phase cartridge and then eluted with the HPLC mobile phase. Forty microliters was taken for LC/ESI-MS analysis using electrospray ionization operated in the positive ion mode. Using the standard method of addition of 5-MTHFA to serum, a linear dilution curve (y = 12.777x - 1.404; range 0.94-97 ng ml(-1)) was constructed. The precision of the method was 5.3% (CV) based on the analysis of four sample replicates. The mass spectrum produced upon collision induced dissociation of the analyte in serum was used to confirm the identity of the 5-MTHFA. The method was applied to the analysis of a set of serum samples that contained standardized concentrations of 5-MTHFA. The determinations of 5-MTHFA in these samples using the LC/ESI-MS procedure were found to be in good agreement with other folate methods. A highly accurate and specific method for the analysis of 5-MTHFA in serum has been developed utilizing stable isotope dilution mass spectrometry. (C) 2001 Academic Press.
引用
收藏
页码:299 / 305
页数:7
相关论文
共 11 条
[1]  
Bagley PJ, 2000, CLIN CHEM, V46, P404
[2]  
CHERUPPOLIL R, 1997, METHOD ENZYMOL, V261, P26
[3]   Determination of blood folate using acid extraction and internally standardized gas chromatography-mass spectrometry detection [J].
Dueker, SR ;
Lin, YM ;
Jones, AD ;
Mercer, R ;
Fabbro, E ;
Miller, JW ;
Green, R ;
Clifford, AJ .
ANALYTICAL BIOCHEMISTRY, 2000, 283 (02) :266-275
[4]  
Gunter EW, 1996, CLIN CHEM, V42, P1689
[5]   A quantitative stable-isotope LC-MS method for the determination of folic acid fortified foods [J].
Pawlosky, RJ ;
Flanagan, VP .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) :1282-1286
[6]   QUANTITATION OF RED-BLOOD-CELL FOLATES BY STABLE-ISOTOPE DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY UTILIZING A FOLATE INTERNAL STANDARD [J].
SANTHOSHKUMAR, CR ;
DEUTSCH, JC ;
HASSELL, KL ;
KOLHOUSE, NM ;
KOLHOUSE, JF .
ANALYTICAL BIOCHEMISTRY, 1995, 225 (01) :1-9
[7]  
SEYOUM E, 1993, J NUTR BIOCH, V4, P448
[8]  
Shane B., 1995, FOLATE HLTH DIS, P1
[9]   Analysis of some folate monoglutamates by high-performance liquid chromatography-mass spectrometry. I [J].
Stokes, P ;
Webb, K .
JOURNAL OF CHROMATOGRAPHY A, 1999, 864 (01) :59-67
[10]   THE THRESHOLD GROWTH-RESPONSE OF LACTOBACILLUS-CASEI TO 5-METHYL-TETRAHYDROFOLIC ACID - IMPLICATIONS FOR FOLATE ASSAYS [J].
WRIGHT, AJA ;
PHILLIPS, DR .
BRITISH JOURNAL OF NUTRITION, 1985, 53 (03) :569-573