Assessment of absorption cooling as a district heating system strategy - A case study

被引:37
作者
Fahlen, Elsa [1 ]
Trygg, Louise [2 ]
Ahlgren, Erik O. [1 ]
机构
[1] Chalmers, Environm & Energy Dept, Div Energy Technol, SE-41296 Gothenburg, Sweden
[2] Linkoping Inst Technol, Dept Mech Engn, Div Energy Syst, SE-58183 Linkoping, Sweden
关键词
Absorption cooling; Compression cooling; Carbon dioxide emissions; Combined heat and power; Industrial excess heat; District heating and cooling; EUROPEAN PERSPECTIVE; UTILITY; COSTS; CHP; OPTIMIZATION; MANAGEMENT; POWER;
D O I
10.1016/j.enconman.2012.02.009
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
Heat load variations, daily as well as seasonal, are constraining co-generation of high-value energy products as well as excess heat utilisation. Integration of heat-driven absorption cooling (AC) technology in a district heating and cooling (DHC) system raises the district heat (DH) demand during low-demand periods and may thus contribute to a more efficient resource utilisation. In Sweden, AC expansion is a potentially interesting option since the cooling demand is rapidly increasing, albeit from low levels, and DH systems cover most of the areas with potential cooling demand. This study aims to assess the potential for cost and CO2 emission reduction due to expansion of DH-driven AC instead of electricity-driven compression cooling in the DHC system of Goteborg, characterised by a high share of low-cost excess heat sources. The DHC production is simulated on an hourly basis using the least-cost model MARTES. Despite recent advances of compression chillers, the results show potential for cost-effective CO2 emission reduction by AC expansion, which is robust with regards to the different scenarios applied of energy market prices and policies. While the effects on annual DHC system results are minor, the study illustrates that an increased cooling demand may be met by generation associated with low or even negative net CO2 emissions - as long as there is high availability of industrial excess heat in the DHC system, or if e.g. new biomass-based combined heat and power capacity is installed, due to the avoided and replaced marginal power generation. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:115 / 124
页数:10
相关论文
共 55 条
[1]
Ahlgren E, 2007, 200723 CEC
[2]
Trigeneration: A comprehensive review based on prime movers [J].
Al-Sulaiman, Fahad A. ;
Hamdullahpur, Feridun ;
Dincer, Ibrahim .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2011, 35 (03) :233-258
[3]
[Anonymous], 2010, World Energy Outlook 2010
[4]
[Anonymous], STAT BIOM PRIC PRISB
[5]
[Anonymous], 2009, STAT SWED DISTR COOL
[6]
[Anonymous], 2005, GAT FEE MIXED WAST Y
[7]
[Anonymous], 1999T2 IEA DISTR HEA, pT2
[8]
[Anonymous], 2006, WORK PACK
[9]
[Anonymous], 2010, FUEL OIL PRIC IND CU
[10]
[Anonymous], ENV REP 2009