A rapid LC-MS method for determination of plasma anion profiles of acidotic patients

被引:9
作者
McKinnon, W
Lord, GA
Forni, LG
Peron, JMR
Hilton, PJ
机构
[1] St Thomas Hosp, Renal Res Lab, Dept Med, London SE1 7EH, England
[2] Univ London Birkbeck Coll, Sch Biol & Chem Sci, MRC, Bioanalyt Sci Grp, London WC1E 7HX, England
[3] Worthing Dist Hosp, Dept Crit Care Med, Worthing BN11 2DH, W Sussex, England
[4] Brighton & Sussex Med Sch, Brighton, E Sussex, England
[5] Kingston Univ, Sch Pharm & Chem, Kingston upon Thames KT1 2EE, Surrey, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 833卷 / 02期
关键词
acidosis; patients; plasma; ultrafiltrate; krebs cycle; anion gap; intermediatry metabolism; liquid chromatography; mass spectrometry;
D O I
10.1016/j.jchromb.2006.01.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In metabolic acidosis, the concentrations of anions associated with intermediary metabolism are increased and can make a significant contribution to the observed acidosis. Here we describe a method for the rapid determination of the plasma ultrafiltrate profile of these anions using liquid chromatography coupled to electrospray ionisation mass spectrometry (LC/ESI-MS). The ultrafiltrate from patients with acidosis resulting from various causes were examined and the results compared to control values. Using the LC/ESI-MS method described, a unique plasma ultrafiltrate anion profile was obtained for each of the groups studied that provides rapid diagnosis of the type of underlying acidosis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 11 条
[1]   RAPID PROFILING OF PLASMA ORGANIC-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DAISH, P ;
LEONARD, JV .
CLINICA CHIMICA ACTA, 1985, 146 (01) :87-91
[2]   Circulating anions usually associated with the Krebs cycle in patients with metabolic acidosis [J].
Forni, LG ;
McKinnon, W ;
Lord, GA ;
Treacher, DF ;
Peron, JMR ;
Hilton, PJ .
CRITICAL CARE, 2005, 9 (05) :R591-R595
[3]   Which organic acids does hemofiltrate contain in the presence of acute renal failure? [J].
Guth, HJ ;
Zschiesche, M ;
Panzig, E ;
Rudolph, PE ;
Jäger, B ;
Kraatz, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (12) :805-810
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MEASUREMENT OF SELECTED BLOOD CITRIC-ACID CYCLE INTERMEDIATES [J].
HAAS, RH ;
BREUER, J ;
HAMMEN, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (01) :47-57
[5]   GAS-CHROMATOGRAPHIC AND GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF ORGANIC-ACIDS IN PLASMA OF PATIENTS WITH CHRONIC-RENAL-FAILURE [J].
LIEBICH, HM ;
PICKERT, A ;
TETSCHNER, B .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :259-266
[6]   3-HYDROXY-3-METHYLGLUTARIC, ADIPIC, AND 2-OXOGLUTARIC ACIDS MEASURED BY HPLC IN THE PLASMA FROM DIABETIC-PATIENTS [J].
LIPPE, G ;
TREVISAN, R ;
NOSADINI, R ;
FABRIS, R ;
DEANA, R .
CLINICAL BIOCHEMISTRY, 1987, 20 (04) :275-279
[7]  
MECHER C, 1991, CRIT CARE MED, V19, P707
[8]  
RACKOW EC, 1990, CIRC SHOCK, V30, P107
[9]   Simultaneous determination of anionic intermediates for Bacillus subtilis metabolic pathways by capillary electrophoresis electrospray ionization mass spectrometry [J].
Soga, T ;
Ueno, Y ;
Naraoka, H ;
Ohashi, Y ;
Tomita, M ;
Nishioka, T .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2233-2239
[10]   QUANTITATIVE METABOLIC PROFILING OF URINARY ORGANIC-ACIDS BY GAS CHROMATOGRAPHY MASS SPECTROMETRY - COMPARISON OF ISOLATION METHODS [J].
THOMPSON, JA ;
MARKEY, SP .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1313-1321