Measuring intraocular pressure-adjustments for corneal thickness and new technologies

被引:94
作者
Herndon, Leon W. [1 ]
机构
[1] Duke Univ, Ctr Eye, Durham, NC 27710 USA
关键词
corneal thickness; glaucoma; intraocular pressure; tonometry;
D O I
10.1097/01.icu.0000193093.05927.a1
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose of review Central corneal thickness has become an important biometric factor and is an essential part of the evaluation of glaucoma. Goldmann applanation tonometry is the most widely used method of measuring intraocular pressure, but it is well known that corneal parameters affect the accuracy of this instrument. Intraocular pressure reduction is currently the only treatment available for decreasing the risk of glaucoma progression, so it is important to have an accurate reading of the true intraocular pressure. Recent findings New tonometers such as the dynamic contour tonometer and the Proview tonometer do not appear to be influenced by central corneal thickness. The ocular response analyzer provides a new measure of corneal biomechanics called corneal hysteresis. Rebound tonometry has been used in animal models of glaucoma, but has recently been compared to Goldmann applanation tonometry in humans. All of these technologies are presented in this review and the influence of corneal thickness on their accuracy is examined. Summary Confronted with the expanding evidence that central corneal thickness is an important ocular parameter that should be measured in clinical practice, eye-care professionals understandably wonder how to best obtain the measurements and what to do with the information. There is wide disagreement among investigators as to if there is an adequately validated 'correction algorithm'; without a validated algorithm, the argument goes, clinicians cannot use the data. These newer technologies may allow clinicians to be able to accurately determine the true intraocular pressure Without having to rely on a correction algorithm.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 46 条
[1]
Assessment of applanation tonometry after hyperopic laser in situ keratomileusis [J].
Alonso-Muñoz, L ;
Lleó-Pérez, A ;
Rahhal, MS ;
Sanchis-Gimeno, JA .
CORNEA, 2002, 21 (02) :156-160
[2]
The proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice [J].
Alvarez, TL ;
Gollance, SA ;
Thomas, GA ;
Greene, RJ ;
Marchetto, PM ;
Moore, EJ ;
Realini, T ;
Liebmann, JM ;
Ritch, R ;
Lama, P ;
Fechtner, RD .
OPHTHALMOLOGY, 2004, 111 (06) :1077-1085
[3]
Intraocular pressure measurement following hyperopic LASIK [J].
Argento, C ;
Cosentino, MJ ;
Moussalli, MA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (02) :145-145
[4]
Ocular hypertension and central corneal thickness [J].
Argus, WA .
OPHTHALMOLOGY, 1995, 102 (12) :1810-1812
[5]
Reduction in intraocular pressure after excimer laser photorefractive keratectomy - Correlation with pretreatment myopia [J].
Chatterjee, A ;
Shah, S ;
Bessant, DA ;
Naroo, SA ;
Doyle, SJ .
OPHTHALMOLOGY, 1997, 104 (03) :355-359
[6]
Copt RP, 1999, ARCH OPHTHALMOL-CHIC, V117, P14
[7]
Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[8]
Tonometry after laser in situ keratomileusis treatment [J].
Duch, S ;
Serra, A ;
Castanera, J ;
Abos, R ;
Quintana, M .
JOURNAL OF GLAUCOMA, 2001, 10 (04) :261-265
[9]
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P652
[10]
EHLERS N, 1974, ACTA OPHTHALMOL, V52, P740