A comparison of immunohistochemical stain quality in conventional and rapid microwave processed tissues

被引:29
作者
Emerson, LL
Tripp, SR
Baird, BC
Layfield, LJ
Rohr, LR
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84132 USA
[2] Univ Utah, Hlth Sci Ctr, Div Nephrol & Hypertens, Salt Lake City, UT 84132 USA
[3] ARUP, Salt Lake City, UT USA
关键词
microwave; tissue processing; immunohistochemistry;
D O I
10.1309/GN6QCBMLLEATLK2M
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Same-day turnaround of pathology specimens is desirable in this era of managed care, and rapid microwave tissue processing produces histologic features of a quality equivalent to overnight processing. We studied whether microwave-assisted rapid tissue processing adversely affects the quality of immunohistochemical staining. We selected 30 specimens (20 neoplastic and 10 nonneoplastic) from our routine surgical pathology workload. Paired large tissue blocks were made from each specimen type, one for microwave-assisted rapid processing and one for conventional processing. Two microarrays of 60 punches each were made from the donor blocks. The microarray blocks were examined for intensity and extent of staining by 44 commonly used antibodies. Slides were reviewed independently by 2 pathologists blinded to the type of processing used. In 5,280 tissue punches examined, we found a high degree of concordance in quality, as measured by intensity and extent of immunohistochemical staining, between microwave and routinely processed tissues. Our study demonstrates that quality of imnumohistochemical staining is similar between rapid microwave and conventional processing. The potential need for imnumohistochemical analysis is not a contraindication for microwave-assisted rapid tissue processing.
引用
收藏
页码:176 / 183
页数:8
相关论文
共 22 条
[1]   High-resolution immunocytochemistry of noncollagenous matrix proteins in rat mandibles processed with microwave irradiation [J].
Arana-Chavez, VE ;
Nanci, A .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2001, 49 (09) :1099-1109
[2]   A RAPID METHOD OF STAINING ULTRATHIN SECTIONS FOR SURGICAL PATHOLOGY TEM WITH THE USE OF THE MICROWAVE OVEN [J].
ESTRADA, JC ;
BRINN, NT ;
BOSSEN, EH .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1985, 83 (05) :639-641
[3]   USE OF MICROWAVES FOR ACID AND ALCOHOL FAST STAINING [J].
HAFIZ, S ;
SPENCER, RC ;
LEE, M ;
GOOCH, H ;
DUERDEN, BI .
JOURNAL OF CLINICAL PATHOLOGY, 1985, 38 (09) :1073-1084
[4]   HISTOPROCESSING WITH THE MICROWAVE-OVEN - AN UPDATE [J].
KOK, LP ;
VISSER, PE ;
BOON, ME .
HISTOCHEMICAL JOURNAL, 1988, 20 (6-7) :323-328
[5]   MAJOR IMPROVEMENT IN MICROSCOPIC-IMAGE QUALITY OF CRYOSTAT SECTIONS - COMBINING FREEZING AND MICROWAVE-STIMULATED FIXATION [J].
KOK, LP ;
BOON, ME ;
SUURMEIJER, AJH .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (05) :620-623
[6]   MICROWAVE FIXATION IN DIAGNOSTIC RENAL PATHOLOGY [J].
LAI, FMM ;
LAI, KN ;
CHEW, EC ;
LEE, JCK .
PATHOLOGY, 1987, 19 (01) :17-21
[7]   ACCELERATED IMMUNOHISTOCHEMICAL STAINING BY MICROWAVES [J].
LEONG, ASY ;
MILIOS, J .
JOURNAL OF PATHOLOGY, 1990, 161 (04) :327-334
[8]   RAPID IMMUNOPEROXIDASE STAINING OF LYMPHOCYTE ANTIGENS USING MICROWAVE IRRADIATION [J].
LEONG, ASY ;
MILIOS, J .
JOURNAL OF PATHOLOGY, 1986, 148 (02) :183-187
[9]   Microwaves and turnaround times in histoprocessing - Is this a new era in histotechnology? [J].
Leong, ASY .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (04) :460-462
[10]   MICROWAVE TECHNIQUES FOR DIAGNOSTIC LABORATORIES [J].
LEONG, ASY .
SCANNING, 1993, 15 (02) :88-98