The iodide/iodate actinometer in UV disinfection: Determination of the fluence rate distribution in UV reactors

被引:76
作者
Rahn, RO [1 ]
Bolton, J [1 ]
Stefan, MI [1 ]
机构
[1] Univ Alabama, Dept Environm Hlth, Birmingham, AL 35294 USA
关键词
D O I
10.1562/2005-06-10-RN-570
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Thirty-seven Suprasil quartz spheres, each approximately 1 cm in diameter and containing an iodide-iodate actinometric solution, were attached to a metal rack and inserted into a bench-scale UV reactor filled with water. The spheres were located at various distances and heights around a 12.4 W low-pressure Hg lamp housed inside a 3.2 cm-radius quartz sleeve in the middle of an annular batch reactor. UV light exposure at 254 nm was performed with the percent transmittance of the water present in the reactor at either 73% or 100% defined over a 1 cm path length. The spheres were simultaneously exposed to the UV light for a given period of time, after which the solutions were removed from the spheres and the yield of triiodide determined from the increase in absorbance at 352 nm. The resulting fluence rate at each site was then calculated on basis of the yield of triiodide. These results were compared with the predictions of a mathematical model based on the multiple point source summation approximation, including reflection and refraction at the air-quartz-water interface. Initially, the agreement was not satisfactory, especially in regions at an oblique angle to the lamp. The model was modified from a multiple point source model to a multiple cylindrical segment model by incorporating a cosine factor. The agreement between the new model and the experimental data was excellent and these experiments provide a strong validation of the model, even under conditions in which the fluence rate varied by > 1000-fold between extreme sites in the reactor.
引用
收藏
页码:611 / 615
页数:5
相关论文
共 9 条
[1]  
Akehata T., 1972, JCHEM ENG JPN, V5, P385, DOI DOI 10.1252/JCEJ.5.385
[2]   Calculation of ultraviolet fluence rate distributions in an annular reactor: Significance of refraction and reflection [J].
Bolton, JR .
WATER RESEARCH, 2000, 34 (13) :3315-3324
[3]   Evaluation of three different lamp emission models using novel application of potassium ferrioxalate actinometry [J].
Quan, Y ;
Pehkonen, SO ;
Ray, MB .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (04) :948-955
[4]  
Rahn R.O., 2000, AM WAT WORKS ASS 200
[5]  
Rahn RO, 2003, PHOTOCHEM PHOTOBIOL, V78, P146, DOI 10.1562/0031-8655(2003)078<0146:QYOTIC>2.0.CO
[6]  
2
[7]   Potassium iodide as a chemical actinometer for 254 nm radiation: Use of iodate as an electron scavenger [J].
Rahn, RO .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1997, 66 (04) :450-455
[8]  
Rahn RO, 1999, PHOTOCHEM PHOTOBIOL, V70, P314, DOI 10.1562/0031-8655(1999)070<0314:DORAGN>2.3.CO
[9]  
2