Software for X-ray fluorescence and scattering tomographic reconstruction

被引:29
作者
Brunetti, A [1 ]
Golosio, B [1 ]
机构
[1] Univ Sassari, Dipartimento Matemat & Fis, I-07100 Sassari, Italy
关键词
tomography; fluorescence; compton; reconstruction algorithm;
D O I
10.1016/S0010-4655(01)00419-2
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Computer tomography is commonly based on transmitted radiation, i.e. the part of the radiation that does not interact with the sample. In recent years the scientific community has demonstrated a growing interest in alternative tomographic techniques, based on fluorescence or on scattered radiation. These kinds of tomography provide complementary information about the sample, e.g., information concerning the spatial distribution of particular elements. Furthermore, they can be applied on experimental situations where a complete turn of the apparatus around the object is not possible. However, fluorescence tomography presents certain additional difficulties in comparison to transmission tomography. This is mainly due to self-absorption effects in the sample. Few algorithms for the correction of such effects are reported in the literature. The solution proposed by Hogan et al. provides a good compromise between image quality and reconstruction speed. In this paper we report an implementation of such an algorithm and also several examples. It is our intention that this paper and the included software represent the first part of a complete set of tools for scattering and fluorescence tomography, which we intend to present in the near future. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:412 / 425
页数:14
相关论文
共 16 条
[1]  
[Anonymous], FUNDAMENTALS DIGITAL
[2]   COMPTON-SCATTERING TOMOGRAPHY IN THE STUDY OF A DENSE INCLUSION IN A LIGHTER MATRIX [J].
BALOGUN, FA ;
SPYROU, NM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (04) :533-538
[3]   Computed tomography in the fatigue test analysis of an asphaltic mixture [J].
Braz, D ;
da Motta, LMG ;
Lopes, RT .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (04) :661-671
[4]   A NEW TOMOGRAPHIC DEVICE BASED ON THE DETECTION OF FLUORESCENT X-RAYS [J].
CESAREO, R ;
MASCARENHAS, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3) :669-672
[5]   X and γ ray tomography for non destructive material testing [J].
Cesareo, R ;
Brunetti, A ;
Lopes, RT ;
Galli, G ;
Rao, DV ;
Castellano, A ;
Gigante, GE ;
Mascarenhas, S ;
Robert, R ;
Swinka, V ;
Gilardoni, M ;
Da Silva, HP ;
Colosso, PQ .
DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 :292-303
[6]   ATTENUATION COEFFICIENTS AND TOMOGRAPHIC MEASUREMENTS FOR SOIL IN THE ENERGY-RANGE 10-300 KEV [J].
CESAREO, R ;
DEASSIS, JT ;
CRESTANA, S .
APPLIED RADIATION AND ISOTOPES, 1994, 45 (05) :613-620
[7]  
CULLEN DE, 1989, UCRL50400 L LIV NAT
[8]   RECONSTRUCTION STRATEGY SUITED TO X-RAY-DIFFRACTION TOMOGRAPHY [J].
GRANT, JA ;
MORGAN, MJ ;
DAVIS, JR ;
WELLS, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02) :291-300
[9]  
HERMAN GT, 1980, IMAGE RECONSRUTCTION, P135
[10]   FLUORESCENT COMPUTER-TOMOGRAPHY - A MODEL FOR CORRECTION OF X-RAY ABSORPTION [J].
HOGAN, JP ;
GONSALVES, RA ;
KRIEGER, AS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (06) :1721-1727