Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry

被引:52
作者
King, RC
Miller-Stein, C
Magiera, DJ
Brann, J
机构
[1] Merck & Co Inc, Dept Drug Metab, West Point, PA 19486 USA
[2] Cohes Technol Inc, Franklin, MA 02038 USA
关键词
D O I
10.1002/rcm.539
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Aria LX4 staggered parallel high performance liquid chromatography (HPLC) system is evaluated for application to good laboratory practice (GLP) level quantitative analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS). This system consists of four fully independent binary HPLC pumps, a modified autosampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Validation results for four different compounds, each analyzed on a separate channel of the Aria system, show precision and accuracy equivalent to that required of a single-channel system. The results show that sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The flexibility and ease of use of the Aria system suggest that it should be possible to quickly implement it in any analytical LC/MS/MS environment. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 38 条
[1]  
Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
[2]  
2-2
[3]  
Biddlecombe RA, 2001, RAPID COMMUN MASS SP, V15, P33, DOI 10.1002/1097-0231(20010115)15:1<33::AID-RCM188>3.0.CO
[4]  
2-4
[5]   Rapid bioanalysis of vancomycin in serum and urine by high-performance liquid chromatography tandem mass spectrometry using on-line sample extraction and parallel analytical columns [J].
Cass, RT ;
Villa, JS ;
Karr, DE ;
Schmidt, DE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (06) :406-412
[6]  
Chen S, 2001, RAPID COMMUN MASS SP, V15, P159, DOI 10.1002/1097-0231(20010130)15:2<159::AID-RCM210>3.0.CO
[7]  
2-W
[8]   Novel in vivo procedure for rapid pharmacokinetic screening of discovery compounds in rats [J].
Cox, KA ;
Dunn-Meynell, K ;
Korfmacher, WA ;
Broske, L ;
Nomeir, AA ;
Lin, CC ;
Cayen, MN ;
Barr, WH .
DRUG DISCOVERY TODAY, 1999, 4 (05) :232-237
[9]  
de Biasi V, 1999, RAPID COMMUN MASS SP, V13, P1165, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1165::AID-RCM638>3.0.CO
[10]  
2-4