A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn's disease

被引:418
作者
Triester, Stuart L.
Leighton, Jonathan A.
Leontiadis, Grigoris I.
Gurudu, Suryakanth R.
Fleischer, David E.
Hara, Amy K.
Heigh, Russell I.
Shiff, Arthur D.
Sharma, Virender K.
机构
[1] Mayo Clin Scottsdale, Div Gastroenterol, Scottsdale, AZ 85259 USA
[2] Mayo Clin Scottsdale, Dept Radiol, Scottsdale, AZ 85259 USA
[3] Univ Thessaloniki, Dept Med 1, GR-54006 Thessaloniki, Greece
关键词
D O I
10.1111/j.1572-0241.2006.00506.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: Capsule endoscopy (CE) allows for direct evaluation of the small bowel mucosa in patients with Crohn's disease (CD). A number of studies have revealed significantly improved yield for CE over other modalities for the diagnosis of CD, but as sample sizes have been small, the true degree of benefit is uncertain. Additionally, it is not clear whether patients with a suspected initial presentation of CD and those with suspected recurrent disease are equally likely to benefit from CE. The aim of this study was to evaluate the yield of CE compared with other modalities in symptomatic patients with suspected or established CD using meta-analysis. METHODS: We performed a recursive literature search of prospective studies comparing the yield of CE to other modalities in patients with suspected or established CD. Data on yield among various modalities were extracted, pooled, and analyzed. Incremental yield (IY) (yield of CE - yield of comparative modality) and 95% confidence intervals (95% CI) of CE over comparative modalities were calculated. Subanalyses of patients with a suspected initial presentation of CD and those with suspected recurrent disease were also performed. RESULTS: Nine studies (n = 250) compared the yield of CE with small bowel barium radiography for the diagnosis of CD. The yield for CE versus barium radiography for all patients was 63% and 23%, respectively (IY = 40%, p < 0.001, 95% CI = 28-51%). Four trials compared the yield of CE to colonoscopy with ileoscopy (n = 114). The yield for CE versus ileoscopy for all patients was 61% and 46%, respectively (IY = 15%, p = 0.02, 95% CI = 2-27%). Three studies compared the yield of CE to computed tomography (CT) enterography/CT enteroclysis (n = 93). The yield for CE versus CT for all patients was 69% and 30%, respectively (IY = 38%, p = 0.001, 95% CI = 15-60%). Two trials compared CE to push enteroscopy (IY = 38%, p < 0.001, 95% CI = 26-50%) and one trial compared CE to small bowel magnetic resonance imaging (MRI) (IY = 22%, p = 0.16, 95% CI = -9% to 53%). Subanalysis of patients with a suspected initial presentation of CD showed no statistically significant difference between the yield of CE and barium radiography (p = 0.09), colonoscopy with ileoscopy (p = 0.48), CT enterography (p = 0.07), or push enteroscopy (p = 0.51). Subanalysis of patients with established CD with suspected small bowel recurrence revealed a statistically significant difference in yield in favor of CE compared with all other modalities (barium radiography (p < 0.001), colonoscopy with ileoscopy (p = 0.002), CT enterography (p < 0.001), and push enteroscopy (p < 0.001)). CONCLUSIONS: In study populations, CE is superior to all other modalities for diagnosing non-stricturing small bowel CD, with a number needed to test (NNT) of 3 to yield one additional diagnosis of CD over small bowel barium radiography and NNT = 7 over colonoscopy with ileoscopy. These results are due to a highly significant IY with CE over all other modalities in patients with established non-stricturing CD being evaluated for a small bowel recurrence. While there was no significant difference seen between CE and alternate modalities for diagnosing small bowel CD in patients with a suspected initial presentation of CD, the trend toward significance for a number of modalities suggests the possibility of a type II error. Larger studies are needed to better establish the role of CE for diagnosing small bowel CD in patients with a suspected initial presentation of CD.
引用
收藏
页码:954 / 964
页数:11
相关论文
共 18 条
[1]   Wireless Capsule Endoscopy requiring surgical intervention: The world's experience [J].
Barkin, JS ;
Friedman, S .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (09) :S298-S298
[2]  
BLOOM P, 2003, 2 INT C CAPS END CHA
[3]   Vidcocapsulc endoscopy versus barium contrast studies for the diagnosis of Crohn's disease recurrence involving the small intestine [J].
Buchman, AL ;
Miller, FH ;
Wallin, A ;
Chowdhry, AA ;
Ahn, C .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (11) :2171-2177
[4]   Capsule endoscopy vs. push enteroscopy and enteroclysis in suspected small-bowel Crohn's disease [J].
Chong, AKH ;
Taylor, A ;
Miller, A ;
Hennessy, O ;
Connell, W ;
Desmond, P .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (02) :255-261
[5]   A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease [J].
Costamagna, G ;
Shah, SK ;
Riccioni, ME ;
Foschia, F ;
Mutignani, M ;
Perri, V ;
Vecchioli, A ;
Brizi, MG ;
Picciocchi, A ;
Marano, P .
GASTROENTEROLOGY, 2002, 123 (04) :999-1005
[6]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188
[7]  
Dubcenco E, 2004, GASTROINTEST ENDOSC, V59, pAB174
[8]   Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634
[9]   Wireless capsule video endoscopy compared to barium follow-through and computerised tomography in patients with suspected Crohn's disease - final report [J].
Eliakim, R ;
Suissa, A ;
Yassin, K ;
Katz, D ;
Fischer, D .
DIGESTIVE AND LIVER DISEASE, 2004, 36 (08) :519-522
[10]  
GOLDER SK, 2005, INT J COLORECTA DIS