Nicotine derivative optode membrane with nonactin as ionophore

被引:10
作者
Choi, MMF [1 ]
Chung, KOP [1 ]
Wu, XJ [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Hong Kong, Hong Kong, Peoples R China
关键词
nicotine; optode membrane; nonactin;
D O I
10.1016/S0039-9140(01)00590-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasticised poly(vinyl chloride) optode membrane incorporated with nonactin as ionophore, ETH 5294 as H+-selective chromoionophore and potassium tetrakis(4-chlorophenyl)borate as anionic site, was used as a reversible sensing device for indirect determination of nicotine. Nicotine was extracted from cigarette samples and converted to its bromoethane derivative (ND+Br-) by reacting with a solution of bromoethane in ethanol. ND+Br-, in a solution of Tris (hydroxymethyl)aminomethane-HCl buffer, was extracted into the bulk of the optode membrane and subsequently caused changes in optical absorption of the sensing layer. The pH effect, response mechanisms, response behaviour, response time, dynamic working range, detection limit, sensitivity and selectivity were discussed in detail. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1027 / 1038
页数:12
相关论文
共 33 条
[1]   Spectrophotometric determination of nicotine [J].
Al-Tamrah, SA .
ANALYTICA CHIMICA ACTA, 1999, 379 (1-2) :75-80
[2]   Comparative study on camphor enantiomers behavior under the conditions of gas-liquid chromatography and reversed-phase high-performance liquid chromatography systems modified with α- and β-cyclodextrins [J].
Asztemborska, M ;
Bielejewska, A ;
Duszczyk, K ;
Sybilska, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (01) :73-80
[3]   DETERMINATION OF NICOTINE IN TOBACCO BY CIRCULAR-DICHROISM SPECTROPOLARIMETRY [J].
ATKINSON, WM ;
HAN, SM ;
PURDIE, N .
ANALYTICAL CHEMISTRY, 1984, 56 (11) :1947-1950
[4]   The acid-base chemistry of nicotine: Extensions, analogies, and a generalization [J].
Ault, A .
JOURNAL OF CHEMICAL EDUCATION, 2001, 78 (04) :500-503
[5]   ATOMIC-ABSORPTION DETERMINATION OF NICOTINE IN TOBACCO [J].
AYAD, MM ;
KHAYYAL, SE ;
FARAG, NM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 (08) :1127-1131
[6]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[7]   SELECTIVITY OF CALIX[4]ARENE CROWN-6 FOR CESIUM ION IN ISE - EFFECT OF THE CONFORMATION [J].
BOCCHI, C ;
CARERI, M ;
CASNATI, A ;
MORI, G .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4234-4238
[8]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[9]  
Chan WH, 1998, ANAL CHIM ACTA, V370, P259
[10]   Optode membrane for determination of nicotine via generation of its bromoethane derivative [J].
Choi, MMF ;
Wu, XJ ;
Li, YR .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1342-1349