Quantitative evaluation of vessel tracking techniques on coronary angiograms

被引:21
作者
Sen, A [1 ]
Lan, L [1 ]
Doi, K [1 ]
Hoffmann, KR [1 ]
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
vessel tracking; coronary angiograms; blood vessels; vessel centerline; quantitative analysis;
D O I
10.1118/1.598575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate, automated determination of vessel center lines is essential for two- and three-dimensional analysis of the coronary vascular tree. Therefore, we have been developing techniques for vessel tracking and for evaluating their accuracy and precision in clinical images. After points in vessels are manually indicated, the vessels are tracked automatically by means of a modified sector-search approach. The perimeters of sectors centered on previous tracking points are searched for the pixels with the maximum contrast. The sector size and radius are automatically adjusted based on local vessel tortuosity. The performance of the tracking technique in regions of high-intensity background is improved by application of a nonlinear adaptive filtering technique in which the vessel signal is effectively removed prior to background estimation. The tracking results were evaluated visually and by calculation of distances between the tracked and user-indicated centerlines, which were used as the "truth." Two hundred and fifty-six coronary vessels were tracked in 32 angiograms. Vessels as small as 0.6 mm in diameter were tracked accurately. This technique correctly tracked 255/256 (>99%) vessels based on an average of 2-3 indicated points per vessel. The one incorrect tracking result was due to a low signal-to-noise ratio (SNR<2). The distance between the tracked and the "true" centerlines ranged from 0.4 to 1.8 pixels, with an average of 0.8 pixels. These results indicate that this technique can provide a reliable basis for 2D and 3D vascular analysis. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02205-1].
引用
收藏
页码:698 / 706
页数:9
相关论文
共 35 条
[1]  
ALPERIN N, 1989, IEEE COMPUTERS CARDI, P153
[2]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[3]  
BURSCH JH, 1981, RADIOLOGY, V141, P39
[4]  
CHEN SJ, 1996, IEEE COMPUTERS CARDI, P117
[5]   Three-dimensional reconstruction of coronary arterial tree based on biplane angiograms [J].
Chen, SYJ ;
Hoffmann, KR ;
Carroll, JD .
MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 :103-114
[6]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[7]   OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS [J].
DETRE, KM ;
WRIGHT, E ;
MURPHY, ML ;
TAKARO, T .
CIRCULATION, 1975, 52 (06) :979-986
[8]   SUDDEN CARDIAC DEATH WITHOUT WARNING - POSSIBLE MECHANISMS AND IMPLICATIONS FOR SCREENING ASYMPTOMATIC POPULATIONS [J].
EPSTEIN, SE ;
QUYYUMI, AA ;
BONOW, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 321 (05) :320-324
[9]   MEASUREMENT OF ABSOLUTE FLOW-RATE IN VESSELS USING A STEREOSCOPIC DSA SYSTEM [J].
FENCIL, LE ;
DOI, K ;
CHUA, KG ;
HOFFMAN, KR .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :659-671
[10]   OBJECT-BASED 3-D RECONSTRUCTION OF ARTERIAL TREES FROM MAGNETIC-RESONANCE ANGIOGRAMS [J].
FESSLER, JA ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) :25-39