A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine

被引:175
作者
Merc, Matjaz [1 ]
Drstvensek, Igor [2 ]
Vogrin, Matjaz [1 ]
Brajlih, Tomaz [2 ]
Recnik, Gregor [1 ]
机构
[1] UKC Maribor, Dept Orthopaed Surg, Maribor 2000, Slovenia
[2] Univ Maribor, Fac Mech Engn, Maribor 2000, Slovenia
关键词
Fluoroscopy; Free-hand; Navigation; Pedicle violation; Vertebra; ASSISTED ORTHOPEDIC-SURGERY; INSTRUMENTATION; CAOS;
D O I
10.1007/s00402-013-1755-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The method of free-hand pedicle screw placement is generally safe although it carries potential risks. For this reason, several highly accurate computer-assisted systems were developed and are currently on the market. However, these devices have certain disadvantages. We have developed a method of pedicle screw placement in the lumbar and sacral region using a multi-level drill guide template, created with the rapid prototyping technology and have validated it in a clinical study. The aim of the study was to manufacture and evaluate the accuracy of a multi-level drill guide template for lumbar and first sacral pedicle screw placement and to compare it with the free-hand technique under fluoroscopy supervision. In 2011 and 2012, a randomized clinical trial was performed on 20 patients. 54 screws were implanted in the trial group using templates and 54 in the control group using the fluoroscopy-supervised free-hand technique. Furthermore, applicability for the first sacral level was tested. Preoperative CT-scans were taken and templates were designed using the selective laser sintering method. Postoperative evaluation and statistical analysis of pedicle violation, displacement, screw length and deviation were performed for both groups. The incidence of cortex perforation was significantly reduced in the template group; likewise, the deviation and displacement level of screws in the sagittal plane. In both groups there was no significantly important difference in deviation and displacement level in the transversal plane as not in pedicle screw length. The results for the first sacral level resembled the main investigated group. The method significantly lowers the incidence of cortex perforation and is therefore potentially applicable in clinical practice, especially in some selected cases. The applied method, however, carries a potential for errors during manufacturing and practical usage and therefore still requires further improvements.
引用
收藏
页码:893 / 899
页数:7
相关论文
共 19 条
[1]
Berlemann U, 1997, ORTHOPADE, V26, P463
[2]
Personalised image-based templates for intra-operative guidance [J].
Berry, E ;
Cuppone, M ;
Porada, S ;
Millner, PA ;
Rao, A ;
Chiverton, N ;
Seedhom, BB .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H2) :111-118
[3]
Computer-assisted orthopedic surgery with individual templates and comparison to conventional operation method [J].
Birnbaum, K ;
Schkommodau, E ;
Decker, N ;
Prescher, A ;
Klapper, U ;
Radermacher, K .
SPINE, 2001, 26 (04) :365-369
[4]
Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? Presented at the 2009 Joint Spine Section Meeting Laboratory investigation [J].
Brasiliense, Leonardo B. C. ;
Theodore, Nicholas ;
Lazaro, Bruno C. R. ;
Sayed, Zafar A. ;
Deniz, Fatih Ersay ;
Sonntag, Volker K. H. ;
Crawford, Neil R. .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (05) :503-508
[5]
Drstvensek I., 2008, Intern Jour of Biol and Biomed Eng, V1, P29
[6]
Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2 [J].
Goffin, J ;
Van Brussel, K ;
Martens, K ;
Vander Sloten, J ;
Van Audekercke, R ;
Smet, MH .
SPINE, 2001, 26 (12) :1343-1347
[7]
Infection in the operating room [J].
Hughes, SPF ;
Anderson, FM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :754-755
[8]
Accuracy of computerized frameless stereotactic image-guided pedicle screw placement into previously fused lumbar spines [J].
Lim, MR ;
Girardi, FP ;
Yoon, SC ;
Huang, RC ;
Cammisa, FP .
SPINE, 2005, 30 (15) :1793-1798
[9]
Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template [J].
Lu, Sheng ;
Zhang, Yuan Z. ;
Wang, Zheng ;
Shi, Ji H. ;
Chen, Yu B. ;
Xu, Xing M. ;
Xu, Yong Q. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (07) :751-758
[10]
A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study [J].
Lu, Sheng ;
Xu, Yong Q. ;
Zhang, Yuan Z. ;
Li, Yan B. ;
Xie, L. E. ;
Shi, Ji H. ;
Guo, Hai ;
Chen, Guo P. ;
Chen, Yu B. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02) :184-191