Duodenal perforation with an inferior vena cava filter: An unusual cause of abdominal pain

被引:65
作者
Feezor, RJ
Huber, TS
Welborn, MB
Schell, SR
机构
[1] Univ Florida, Coll Med, Dept Surg, Gainesville, FL 32610 USA
[2] Univ Florida, Coll Med, Dept Microbiol & Mol Genet, Gainesville, FL 32610 USA
[3] Malcolm Randall Vet Affairs Med Ctr, Gainesville, FL USA
关键词
D O I
10.1067/mva.2002.121567
中图分类号
R61 [外科手术学];
学科分类号
摘要
The insertion of inferior vena cava (IVC) filters results in device migration at rates that exceed 50% in some studies, although the clinical significance of migration remains in question. These filters can also erode or penetrate the IVC wall, injuring adjacent retroperitoneal and abdominal structures. The risk of erosion or perforation is estimated to be as much as 25%, although clinical symptoms are observed far less frequently in patients with these complications. We describe the presentation, evaluation, and treatment of a patient with an IVC strut protruding into the duodenum. This case report discusses complications, presenting symptoms, and treatment of patients with IVC filters complications.
引用
收藏
页码:1010 / 1012
页数:3
相关论文
共 16 条
[1]   INFERIOR VENA-CAVA FILTERS - INDICATIONS, SAFETY, EFFECTIVENESS [J].
BECKER, DM ;
PHILBRICK, JT ;
SELBY, JB .
ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (10) :1985-1994
[2]  
Bonn J, 1999, J VASC SURG, V30, P573
[3]   COMPLICATIONS ENCOUNTERED WITH THE USE OF THE GREENFIELD FILTER [J].
CARABASI, RA ;
MORITZ, MJ ;
JARRELL, BE .
AMERICAN JOURNAL OF SURGERY, 1987, 154 (02) :163-168
[4]   LATE COMPLICATION OF A GREENFIELD FIL TER ASSOCIATING CAUDAL MIGRATION AND PERFORATION OF THE ABDOMINAL-AORTA BY A RUPTURED STRUT [J].
DABBAGH, A ;
CHAKFE, N ;
KRETZ, JG ;
DEMRI, B ;
NICOLINI, P ;
FUENTES, C ;
METTAUER, B ;
EPAILLY, E ;
MUSTER, D ;
EISENMANN, B .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (02) :182-187
[5]  
GELBFISH GA, 1991, J VASC SURG, V14, P614
[6]   Ureteral injury secondary to an inferior vena caval filter [J].
Goldman, HB ;
Hanna, K ;
Dmochowski, RR .
JOURNAL OF UROLOGY, 1996, 156 (05) :1763-1763
[7]  
Goldman K A, 1994, Cardiovasc Surg, V2, P85
[8]  
GREENFIELD LJ, 1988, SURGERY, V104, P706
[9]   Tricuspid insufficiency after intracardiac migration of a Greenfield filter: Case report and review of the literature [J].
James, KV ;
Sobolewski, AP ;
Lohr, JM ;
Welling, RE .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (03) :494-498
[10]   SPONTANEOUS DISRUPTION OF 2 GREENFIELD VENA-CAVAL FILTERS [J].
LANG, W ;
SCHWEIGER, H ;
FIETKAU, R ;
HOFMANNPREISS, K .
RADIOLOGY, 1990, 174 (02) :445-446