Dissociation of bipolar hemiarthroplasty of the hip after dislocation - A report of five different cases and review of literature

被引:27
作者
Georgiou, G [1 ]
Siapkara, A [1 ]
Dimitrakopoulou, A [1 ]
Provelengios, S [1 ]
Dounis, E [1 ]
机构
[1] Laiko Gen Hosp Athens, Dept Orthopaed, Athens 11527, Greece
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2006年 / 37卷 / 02期
关键词
dissociation; dislocation; bipolar hemiarthroplasty; hip fractures; revision;
D O I
10.1016/j.injury.2005.09.014
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Little information is available about the rare but serious disadvantage of dissociation of modular components during dislocation or after close reduction in the bipolar hemiarthroplasty of the hip. In most cases, simple dislocation after primary bipolar. hemiarthroplasty can safety be reduced by close methods. Dissociation leads almost always to reoperation and possible revision of the prosthesis. To avoid this complication, strict adherence to the surgical technique during the initial procedure and extra precaution during close reduction are recommended, in order to provide enhanced security over component disassembly. In the five cases presented in this study, dissociation is reported at different circumstances, along with the different methods of treatment required in each patient. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:162 / 168
页数:7
相关论文
共 14 条
[1]
DISLOCATION AFTER BIPOLAR HEMIARTHROPLASTY OF THE HIP [J].
BARNES, CL ;
BERRY, DJ ;
SLEDGE, CB .
JOURNAL OF ARTHROPLASTY, 1995, 10 (05) :667-669
[2]
BIPOLAR HEMIARTHROPLASTY FOR FRACTURE OF THE FEMORAL-NECK - CLINICAL REVIEW WITH SPECIAL EMPHASIS ON PROSTHETIC MOTION [J].
BOCHNER, RM ;
PELLICCI, PM ;
LYDEN, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (07) :1001-1010
[3]
OSTEOLYSIS OF THE ACETABULUM ASSOCIATED WITH A BIPOLAR HEMIARTHROPLASTY - A LATE COMPLICATION [J].
BOSE, WJ ;
MILLER, GJ ;
PETTY, W .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) :1733-1735
[4]
Failure of the polyethylene after bipolar hemiarthroplasty of the hip - A report of five cases [J].
Calton, TF ;
Fehring, TK ;
Griffin, WL ;
McCoy, TH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (03) :420-423
[5]
Corteel J, 1996, Acta Orthop Belg, V62, P173
[6]
A survey of the treatment of displaced intracapsular femoral neck fractures in the UK [J].
Crossman, PT ;
Khan, RJK ;
MacDowell, A ;
Gardner, AC ;
Reddy, NS ;
Keene, GS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (05) :383-386
[7]
Cemented bipolar hemiarthroplasty for displaced intracapsular fracture in the mobile active elderly patient [J].
Dixon, S ;
Bannister, G .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (02) :152-156
[8]
Goldhill V B, 1991, J Orthop Trauma, V5, P318, DOI 10.1097/00005131-199109000-00011
[9]
Loubignac F, 1997, REV CHIR ORTHOP REPA, V84, P469
[10]
Unipolar versus bipolar hemiarthroplasty: Functional outcome after femoral neck fracture at a minimum of thirty-six months of follow-up [J].
Ong, BC ;
Maurer, SG ;
Aharonoff, GB ;
Zuckerman, JD ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :317-322