Electrochemical oxidation of chlorophenols at a boron-doped diamond electrode and their determination by high-performance liquid chromatography with amperometric detection

被引:163
作者
Terashima, C [1 ]
Rao, TN [1 ]
Sarada, BV [1 ]
Tryk, DA [1 ]
Fujishima, A [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
关键词
D O I
10.1021/ac010681w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodically pretreated. diamond electrodes have been used for the detection of chlorophenols (CPs) in environmental water samples after high-performance liquid chromatographic (HPLC separation. The anodization of as-deposited boron-doped polycrystalline diamond thin-film electrodes has enabled the stable determination of phenols over a wide concentration range. Prior to the HPLC analysis, a comparative study with ordinary glassy carbon, as-deposited diamond, and anodized diamond was made to examine the oxidative behavior of phenols by cyclic voltammety and flow injection analysis with amperometric detection. At anodized diamond electrodes, reproducible, well-defined cyclic voltammograms were obtained even at high CP concentration (5 mM), due to a low proclivity for adsorption of the oxidation products on the surface. In addition, after prolonged use, the partially deactivated diamond could be reactivated on line by applying a highly anodic potential (2.64 Vvs SCE) for 4 min, which enabled the destruction of the electrodeposited polymer deposits. Hydroxyl radicals produced by the high applied potential, in which oxygen evolution occurs, are believed to be responsible for the oxidation of the passivating layer on the surface. When coupled with flow injection analysis (FIA), anodized diamond exhibited excellent stability, with a response variability of 2.3% (n = 100), for the oxidation of a high concentration (5 mM) of chlorophenol. In contrast, glassy carbon exhibited a response variability of 39.1%. After 100 injections, the relative peak intensity, for diamond decreased by 10%, while a drastic decrease of 70% was observed for glassy carbon. The detection limit obtained in the FIA mode for 2,4-dichlorophenol was found to be 20 nM (S/N = 3), with a linear dynamic range up to 100 muM. By coupling with the column-switching technique, which enabled on-line preconcentration (50 times), the, detection limit was lowered to 0.4 nM (S/N = 3). By use of this technique, anodized diamond electrodes were demonstrated for the analysis of CPs in drainwater that was condensed from the flue gas of waste incinerators.
引用
收藏
页码:895 / 902
页数:8
相关论文
共 44 条
[1]   Voltammetry - Spanning the kinetic timescale [J].
Alden, JA ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :198A-203A
[2]   Relative rates of formation of polychlorinated dioxins and furans from precursor and de novo reactions [J].
Altwicker, ER .
CHEMOSPHERE, 1996, 33 (10) :1897-1904
[3]  
BUB FP, 1973, BER BUNSEN PHYS CHEM, V77, P823
[4]   Liquid chromatography/electrochemical detection of phenols at a poly[Ni-(Protoporphyrin IX)] chemically modified electrode [J].
DallOrto, VC ;
Danilowicz, C ;
Sobral, S ;
LoBalbo, A ;
Rezzano, I .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :195-199
[5]  
DeScure V., 1981, CAN J CHEM ENG, V59, P852
[6]  
DOBOS D, 1975, ELECTROCHEMICAL DATA, P239
[7]   A nanosecond laser flash photolysis study of aqueous 4-chlorophenol [J].
Durand, AP ;
Brown, RG ;
Worrall, D ;
Wilkinson, F .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 1996, 96 (1-3) :35-43
[8]   AN ATTEMPT TO DEFINE BENZENE AND PHENOL ELECTROCHEMICAL OXIDATION MECHANISM [J].
FLESZAR, B ;
PLOSZYNSKA, J .
ELECTROCHIMICA ACTA, 1985, 30 (01) :31-42
[9]   Oxidation of organics by intermediates of water discharge on IrO2 and synthetic diamond anodes [J].
Fóti, G ;
Gandini, D ;
Comninellis, C ;
Perret, A ;
Haenni, W .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (05) :228-230
[10]  
Fryda M, 1999, NEW DIAM FRONT C TEC, V9, P229