Thoracic and respirable particle definitions for human health risk assessment

被引:367
作者
Brown, James S. [1 ]
Gordon, Terry [2 ]
Price, Owen [3 ]
Asgharian, Bahman [4 ]
机构
[1] US EPA, Natl Ctr Environm Assessment, Raleigh, NC 27711 USA
[2] NYU, Sch Med, Tuxedo Pk, NY 10987 USA
[3] Appl Res Associates Inc, Arlington, VA 22203 USA
[4] Appl Res Associates Inc, Raleigh, NC 27615 USA
关键词
Size-selective sampling; Fine and coarse particles; ORONASAL DISTRIBUTION; REGIONAL DEPOSITION; NASAL CONTRIBUTION; VENTILATION; CHILDREN; AIRWAYS; ADULTS; INHALABILITY; CLEARANCE; EXERCISE;
D O I
10.1186/1743-8977-10-12
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 [卫生毒理学];
摘要
Background: Particle size-selective sampling refers to the collection of particles of varying sizes that potentially reach and adversely affect specific regions of the respiratory tract. Thoracic and respirable fractions are defined as the fraction of inhaled particles capable of passing beyond the larynx and ciliated airways, respectively, during inhalation. In an attempt to afford greater protection to exposed individuals, current size-selective sampling criteria overestimate the population means of particle penetration into regions of the lower respiratory tract. The purpose of our analyses was to provide estimates of the thoracic and respirable fractions for adults and children during typical activities with both nasal and oral inhalation, that may be used in the design of experimental studies and interpretation of health effects evidence. Methods: We estimated the fraction of inhaled particles (0.5-20 mu m aerodynamic diameter) penetrating beyond the larynx (based on experimental data) and ciliated airways (based on a mathematical model) for an adult male, adult female, and a 10 yr old child during typical daily activities and breathing patterns. Results: Our estimates show less penetration of coarse particulate matter into the thoracic and gas exchange regions of the respiratory tract than current size-selective criteria. Of the parameters we evaluated, particle penetration into the lower respiratory tract was most dependent on route of breathing. For typical activity levels and breathing habits, we estimated a 50% cut-size for the thoracic fraction at an aerodynamic diameter of around 3 mu m in adults and 5 mu m in children, whereas current ambient and occupational criteria suggest a 50% cut-size of 10 mu m. Conclusions: By design, current size-selective sample criteria overestimate the mass of particles generally expected to penetrate into the lower respiratory tract to provide protection for individuals who may breathe orally. We provide estimates of thoracic and respirable fractions for a variety of breathing habits and activities that may benefit the design of experimental studies and interpretation of particle size-specific health effects.
引用
收藏
页数:12
相关论文
共 33 条
[1]
ACGIH, 2015, AM C GOV IND HYG CIN
[2]
American Conference of Governmental Industrial Hygienis (ACGIH), 1985, PART SIZ SEL SAMPL W
[3]
A MULTIPLE-PATH MODEL OF PARTICLE DEPOSITION IN THE RAT LUNG [J].
ANJILVEL, S ;
ASGHARIAN, B .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1995, 28 (01) :41-50
[4]
[Anonymous], 1994, ANN ICRP, DOI [10.1016/0146-6453(94)90004-3, DOI 10.1016/0146-6453(94)90004-3]
[5]
[Anonymous], 1987, FED REGISTER, V52, P24634
[6]
BECQUEMIN MH, 1991, EUR RESPIR J, V4, P694
[7]
Oronasal ventilation partitioning in adults and children: Effect on aerosol deposition in airways [J].
Becquemin, MM ;
Bertholon, JF ;
Bouchikhi, A ;
Malarbet, JL ;
Roy, M .
RADIATION PROTECTION DOSIMETRY, 1999, 81 (03) :221-228
[8]
Bronchial airway deposition and retention of particles in inhaled boluses: effect of anatomic dead space [J].
Bennett, WD ;
Scheuch, G ;
Zeman, KL ;
Brown, JS ;
Kim, C ;
Heyder, J ;
Stahlhofen, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (02) :685-694
[9]
Nasal contribution to breathing with exercise: effect of race and gender [J].
Bennett, WD ;
Zeman, KL ;
Jarabek, AM .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (02) :497-503
[10]
Bennett WD, 1997, ANN OCCUP HYG, P497