Effect of balloon-expandable and self-expanding stent fixation on endoluminal polytetrafluoroethylene graft healing

被引:7
作者
Ombrellaro, MP [1 ]
Stevens, SL [1 ]
Sciarrotta, J [1 ]
Schaeffer, DO [1 ]
Freeman, MB [1 ]
Goldman, MH [1 ]
机构
[1] UNIV TENNESSEE, MED CTR, DEPT SURG, DIV VASC SURG, KNOXVILLE, TN 37920 USA
关键词
D O I
10.1016/S0002-9610(97)00017-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
PURPOSE: To investigate the effect of stent design and deployment mechanism on endoluminal graft healing. METHOD: Twenty dogs underwent infrarenal abdominal aorta polytetrafluoroethylene (PTFE) interposition (6) or intraluminal stented grafting using either a balloon expandable (BE, n = 8) or self-expanding (SE, n = 6) stent design, Grafts were removed at 8 weeks. Length of endothelial ingrowth and intima to media height ratios (IMHR) were calculated. Perianastomotic smooth muscle (Actin+), macrophage (CD44+), proliferating (PCNA+), and platelet-derived growth factor (PDGF+) cell content were determined. RESULTS: Mean endothelial ingrowth was 1.10 +/- 0.15 cm (control), 1.88 +/- 0.13 cm (BESG), and 2.16 +/- 0.18 cm (SESG) proximally; and 0.94 +/- 0.12, 2.11 +/- 0.11 cm, and 2.16 +/- 0.15 cm, respectively, at the distal anastomosis. Endothelial ingrowth was greater in all stented grafts (P < 0.001). Mean IMHRs were 1.42 +/- 0.16 (control), 0.50 +/- 0.14 (BESG), and 0.77 +/- 0.2 (SESG) proximally; and 0.84 +/- 0.1, 0.42 +/- 0.09, and 0.77 +/- 0.12 (SESG) distally, Lower IMHRs were observed in all stented graft regions (P < 0.05) except the distal anastomosis of SESG, The PDGF+ and PCNA+ cell content was decreased, and Actin+ cell content was increased in all stented grafts (P < 0.05). CONCLUSION: Intraluminal location enhances endothelialization and attenuates intimal thickening in PTFE grafts, The enhanced healing of intraluminal stented grafts is irrespective of the type of stent or deployment mechanism used. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 28 条
[1]   EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[2]   IN-VITRO EVALUATION OF ENDOVASCULAR STENTS TO ASSESS SUITABILITY FOR ENDOVASCULAR GRAFT FIXATION [J].
ANDREWS, SM ;
ANSON, AW ;
GREENHALGH, RM ;
NOTT, DM .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 9 (04) :403-407
[3]   CHANGES IN ARTERIAL-WALL COMPLIANCE AFTER ENDOVASCULAR STENTING [J].
BACK, M ;
KOPCHOK, G ;
MUELLER, M ;
CAVAYE, D ;
DONAYRE, C ;
WHITE, RA .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :905-911
[4]   TRANS-FEMORAL PLACEMENT OF INTRALUMINAL POLYURETHANE PROSTHESIS FOR ABDOMINAL AORTIC-ANEURYSM [J].
BALKO, A ;
PIASECKI, GJ ;
SHAH, DM ;
CARNEY, WI ;
HOPKINS, RW ;
JACKSON, BT .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) :305-309
[5]  
BARRA JA, 1986, J THORAC CARDIOV SUR, V92, P330
[6]   EFFECT OF AN ENDOVASCULAR STENT ON HEALING OF AN END-TO-END POLYTETRAFLUOROETHYLENE-ARTERY ANASTOMOSIS IN A CANINE MODEL [J].
CHALMERS, RTA ;
HOBALLAH, JJ ;
SHARP, WJ ;
KRESOWIK, TF ;
CORSON, JD .
BRITISH JOURNAL OF SURGERY, 1994, 81 (10) :1443-1447
[7]   THE EFFECT OF AN INTRALUMINAL STENT ON NEOINTIMAL HYPERPLASIA AT AN END-TO-SIDE POLYTETRAFLUOROETHYLENE GRAFT ARTERIAL ANASTOMOSIS [J].
CHALMERS, RTA ;
HOBALLAH, JJ ;
SHARP, WJ ;
KRESOWIK, TF ;
CORSON, JD .
AMERICAN JOURNAL OF SURGERY, 1994, 168 (02) :85-90
[8]   TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
FIORE, WM ;
DEWEESE, JA ;
QUERAL, LA ;
CRIADO ;
NATH, RL ;
BERKOWITZ, HD ;
SUMPIO, BE .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :185-197
[9]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[10]   INCREASED COMPLIANCE NEAR VASCULAR ANASTOMOSES [J].
HASSON, JE ;
MEGERMAN, J ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1985, 2 (03) :419-423