Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique

被引:50
作者
van Geuns, RJM
de Bruin, HG
Rensing, BJWM
Wielopolski, PA
Hulshoff, MD
van Ooijen, PMA
Oudkerk, M
de Feyter, PJ
机构
[1] Univ Rotterdam Hosp, Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dr Daniel den Hoedklin, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
关键词
magnetic resonance imaging; coronary artery disease; coronary angiography; computer assisted image processing;
D O I
10.1136/hrt.82.4.515
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Magnetic resonance coronary angiography is challenging because of the motion of the vessels during cardiac contraction and respiration. Additional challenges are the small calibre of the arteries and their complex three dimensional course. Respiratory gating, turboflash acquisition, and volume rendering techniques may meet the necessary requirements for appropriate visualisation. Objective-To determine the diagnostic accuracy of respiratory gated magnetic resonance imaging (MRI) for the detection of significant coronary artery stenoses evaluated with three dimensional postprocessing software. Methods-32 patients referred for elective coronary angiography were studied with a retrospective respiratory gated three dimensional gradient echo MRI technique. Resolution was 1.9 x 1.25 x t mm. After manual segmentation three dimensional evaluation was performed with a volume rendering technique. Results-Overall 74% (range 50% to 90%) of the proximal and mid coronary artery segments were visualised with an image quality suitable for further analysis. Sensitivity and specificity for the detection of significant stenoses were 50% and 91%, respectively. Conclusions-Volume rendering of respiratory gated MRI techniques allows adequate visualisation of the coronary arteries in patients with a regular breathing pattern. Significant lesions in the major coronary artery branches can be identified with a moderate sensitivity and a high specificity.
引用
收藏
页码:515 / 519
页数:5
相关论文
共 30 条
[1]   Visualization of the coronary arteries in three-dimensional reconstructions using respiratory gated magnetic resonance imaging [J].
Achenbach, S ;
Kessler, W ;
Moshage, WE ;
Ropers, D ;
Zink, D ;
Kroeker, R ;
Nitz, W ;
Laub, G ;
Bachmann, K .
CORONARY ARTERY DISEASE, 1997, 8 (07) :441-448
[2]  
Austen W G, 1975, Circulation, V51, P5
[3]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[4]   Volume rendering [J].
Drebin, Robert A. ;
Carpenter, Loren ;
Hanrahan, Pat .
Computer Graphics (ACM), 1988, 22 (04) :65-74
[5]  
Duerinckx AJ, 1996, EUR RADIOL, V6, P312
[6]   2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS [J].
DUERINCKX, AJ ;
URMAN, MK .
RADIOLOGY, 1994, 193 (03) :731-738
[7]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[8]  
HOFMAN MBM, 1995, J COMPUT ASSIST TOMO, V19, P56
[9]   CT angiography: Thoracic vascular imaging with interactive volume rendering technique [J].
Johnson, PT ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :110-114
[10]   CT angiography with volume rendering: Advantages and applications in splanchnic vascular imaging [J].
Johnson, PT ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
RADIOLOGY, 1996, 200 (02) :564-568