Biases affecting the measurements of tumor-to-background activity ratio in PET

被引:16
作者
Soret, M [1 ]
Riddell, C [1 ]
Hapdey, S [1 ]
Buvat, I [1 ]
机构
[1] CHU Pitie Salpetriere, U494 INSERM, Paris, France
关键词
attenuation; measurement; partial volume effect; positron emmission tomography (PET); standardized uptake value; tumor;
D O I
10.1109/TNS.2002.803687
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of various factors on the biases affecting tumor-to-background activity ratio (TBR) estimates in positron emission tomography (PET) was studied using analytical simulations of an anthropomorphic phantom. The impact of attenuation correction (AC) on TBR as a function of tumor location and tumor-to-background density ratio was studied. The TBR changes that would be observed when a tumor with uniform uptake turns to a tumor with nonuniform uptake due a necrotic process were characterized. Major parameters affecting the bias in TBR estimates were the tumor diameter, the TBR, whether AC had been performed and the spatial resolution of the PET scanner. Our results suggest that a necrotic process gets detectable if the necrotic volume is at least 50% of the total tumor volume for a necrosis-to-tumor activity ratio of 0.5. We discuss how our results regarding TBR biases translate into standardized uptake values biases.
引用
收藏
页码:2112 / 2118
页数:7
相关论文
共 16 条
[1]  
Avril N, 1997, J NUCL MED, V38, P1186
[2]  
Bengel FM, 1997, EUR J NUCL MED, V24, P1091
[3]   FDG imaging of lung nodules: A phantom study comparing SPECT, camera-based PET, and dedicated PET [J].
Coleman, RE ;
Laymon, CM ;
Turkington, TG .
RADIOLOGY, 1999, 210 (03) :823-828
[4]  
Higashi K, 1998, J NUCL MED, V39, P9
[5]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308
[6]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[7]  
Imran MB, 1998, J NUCL MED, V39, P1219
[8]   ANALYSIS OF EMISSION TOMOGRAPHIC SCAN DATA - LIMITATIONS IMPOSED BY RESOLUTION AND BACKGROUND [J].
KESSLER, RM ;
ELLIS, JR ;
EDEN, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) :514-522
[9]  
KEYES JW, 1995, J NUCL MED, V36, P1836
[10]   Evaluation of pulmonary lesions with FDG-PET - Comparison of findings in patients with and without a history of prior malignancy [J].
Knight, SB ;
Delbeke, D ;
Stewart, JR ;
Sandler, MP ;
Ebers, T .
CHEST, 1996, 109 (04) :982-988