Reliability and validity studies of a new computer-assisted crossed-cylinder aberroscope

被引:8
作者
Cox, MJ
Walsh, G
机构
[1] Department of Optometry, University of Bradford, Bradford, West Yorksbire
[2] Department of Vision Sciences, Glasgow Caledonian University, Glasgow
[3] Department of Optometry, University of Bradford, Bradford BD7 1DP, Richmond Road
关键词
ocular aberrations; aberroscope; reliability; validity; image analysis;
D O I
10.1097/00006324-199707000-00027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. We assessed the reliability and validity of a new computer-assisted crossed-cylinder aberroscope technique which measures the monochromatic optical aberrations of the human eye. Methods. Intra-image variability, the variability occurring when the same image is repeatedly measured, and inter-image variability, the variability occurring when different images collected from the same eye are measured, were assessed using 10 repeated measures on each of 10 different subjects. We compared the measurements made using the computer-assisted technique with manual measurements made when a human operator performed all the aberroscope grid intersection location tasks. Results. One-way repeated measures analyses of variance (ANOVA) on the inter-image and intra-image variability showed that the mean of the measurements made was statistically independent of the occasion on which a group of subjects was measured, and inter-image variability was larger than intra-image variability. A two-way repeated measures ANOVA comparing computer-assisted results with manual results showed that the means of the measurements made with the two methods are not statistically different from one another. The manual results showed greater variability than computer-assisted measurements. Conclusions. The technique is reliable and valid compared to earlier objective crossed-cylinder aberroscopic techniques.
引用
收藏
页码:570 / 580
页数:11
相关论文
共 18 条
[1]  
APPLEGATE R, COMMUNICATION
[2]   ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
WILLIAMS, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02) :195-201
[3]   DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM [J].
ARTAL, P ;
IGLESIAS, I ;
LOPEZGIL, N ;
GREEN, DG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10) :2358-2366
[4]   MEASUREMENT OF MONOCHROMATIC OCULAR ABERRATIONS OF HUMAN EYES AS A FUNCTION OF ACCOMMODATION BY THE HOWLAND ABERROSCOPE TECHNIQUE [J].
ATCHISON, DA ;
COLLINS, MJ ;
WILDSOET, CF ;
CHRISTENSEN, J ;
WATERWORTH, MD .
VISION RESEARCH, 1995, 35 (03) :313-323
[5]   WAVE-FRONT ABERRATION OF THE EYE - A REVIEW [J].
CHARMAN, WN .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (08) :574-583
[6]  
CHARMAN WN, 1991, VISION VISUAL DYSFUN, V1, P1
[7]  
COX MJ, 1997, VISION SCI ITS APPL, V1, P140
[8]  
HOWLAND B, 1968, SCIENCE, V7, P1587
[9]   SUBJECTIVE METHOD FOR MEASUREMENT OF MONOCHROMATIC ABERRATIONS OF EYE [J].
HOWLAND, HC ;
HOWLAND, B .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1977, 67 (11) :1508-1518
[10]   OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR [J].
LIANG, JZ ;
GRIMM, B ;
GOELZ, S ;
BILLE, JF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07) :1949-1957