Monolithic capillary columns for liquid chromatography-electrospray ionization mass spectrometry in proteomic and genomic research

被引:74
作者
Walcher, W
Oberacher, H
Troiani, S
Hölzl, G
Oefner, P
Zolla, L
Huber, CG [1 ]
机构
[1] Univ Saarland, D-66123 Saarbrucken, Germany
[2] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
[3] Univ Tuscia, Dept Environm Sci, I-01100 Viterbo, Italy
[4] Stanford Univ, Genome Technol Ctr, Palo Alto, CA 94304 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 782卷 / 1-2期
关键词
monolithic columns; proteomics; genomics; proteins; peptides; nucleic acids;
D O I
10.1016/S1570-0232(02)00667-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peptides, proteins, single-stranded oligonucleotides, and double-stranded DNA fragments were separated with high resolution in micropellicular, monolithic capillary columns prepared by in situ radical copolymerization of styrene and divinylbenzene. Miniaturized chromatography both in the reversed-phase and the ion-pair reversed-phase mode could be realized in the same capillary column because of the nonpolar character of the poly-(styrene/divinylbenzene) stationary phase. The high chromatographic performance of the monolithic stationary phase facilitated the generation of peak capacities for the biopolymers in the range of 50-140 within 10 min under gradient elution conditions. Employing volatile mobile phase components, separations in the two chromatographic separation modes were on-line hyphenated to electrospray ionization (tandem) mass spectrometry, which yielded intact accurate molecular masses as well as sequence information derived from collision-induced fragmentation. The inaccuracy of mass determination in a quadrupole ion trap mass spectrometer was in the range of 0.01-0.02% for proteins up to a molecular mass of 20 000, and 0.02-0.12% for DNA fragments up to a molecular mass of 310 000. High-performance liquid chromatography-electrospray ionization mass spectrometry utilizing monolithic capillary columns was applied to the identification of proteins by peptide mass fingerprinting, tandem mass spectrometric sequencing, or intact molecular mass determination, as well as to the accurate sizing of double-stranded DNA fragments ranging in size from 50 to 500 base pairs, and to the detection of sequence variations in DNA fragments amplified by the polymerase chain reaction. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:111 / 125
页数:15
相关论文
共 67 条
[1]   ENHANCED SENSITIVITY FOR PEPTIDE-MAPPING WITH ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN THE PRESENCE OF SIGNAL SUPPRESSION DUE TO TRIFLUOROACETIC ACID-CONTAINING MOBILE PHASES [J].
APFFEL, A ;
FISCHER, S ;
GOLDBERG, G ;
GOODLEY, PC ;
KUHLMANN, FE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :177-190
[2]   ELECTROSTATIC RETENTION MODEL OF REVERSED-PHASE ION-PAIR CHROMATOGRAPHY [J].
BARTHA, A ;
STAHLBERG, J .
JOURNAL OF CHROMATOGRAPHY A, 1994, 668 (02) :255-284
[3]   AMINO-ACID SEQUENCING OF PROTEINS [J].
BIEMANN, K ;
PAPAYANNOPOULOS, IA .
ACCOUNTS OF CHEMICAL RESEARCH, 1994, 27 (11) :370-378
[4]   MASS-SPECTROMETRIC METHODS FOR PROTEIN SEQUENCING [J].
BIEMANN, K .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :1288-&
[5]   ANALYSIS OF OLIGONUCLEOTIDES USING COUPLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
BLEICHER, K ;
BAYER, E .
CHROMATOGRAPHIA, 1994, 39 (7-8) :405-408
[6]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[7]   Molecular weight determination of plasmid DNA using electrospray ionization mass spectrometry [J].
Cheng, XH ;
Camp, DG ;
Wu, QY ;
Bakhtiar, R ;
Springer, DL ;
Morris, BJ ;
Bruce, JE ;
Anderson, GA ;
Edmonds, CG ;
Smith, RD .
NUCLEIC ACIDS RESEARCH, 1996, 24 (11) :2183-2189
[8]   Utility of accurate mass tags for proteome-wide protein identification [J].
Conrads, TP ;
Anderson, GA ;
Veenstra, TD ;
Pasa-Tolic, L ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3349-3354
[9]   Resolution and identification of the protein components of the photosystem II antenna system of higher plants by reversed-phase liquid chromatography with electrospray-mass spectrometric detection [J].
Corradini, D ;
Huber, CG ;
Timperio, AM ;
Zolla, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 886 (1-2) :111-121
[10]   DEVELOPMENTS IN MULTIDIMENSIONAL SEPARATION SYSTEMS [J].
CORTES, HJ .