Dielectric properties of tissue-equivalent liquids and their effects on specific absorption rate

被引:39
作者
Fukunaga, K [1 ]
Watanabe, S [1 ]
Yamanaka, Y [1 ]
机构
[1] Commun Res Labs, Tokyo 1848795, Japan
关键词
biological effects of electromagnetic radiation; dielectric liquids; specific absorption rate (SAR);
D O I
10.1109/TEMC.2004.823624
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The radio frequency safety of mobile phones has been evaluated in terms of specific absorption rate (SAR). Standard methods for measurement of the SAR, including recipes for tissue-equivalent dielectric liquids, have recently been the subject of discussion among international standards organizations. Standards currently recommend glycol-type liquids as tissue-equivalent liquids for frequencies above 1 GHz. Although the ingredients are specified in the recipes provided, some fundamental information, such as the stability of dielectric properties, remains unclear. We measured the change of dielectric properties with time and with temperature of tissue-equivalent liquids recommended in the standard documents, and evaluated their effects on SAR. The conductivity decreased with increasing temperature in all glycol-type specimens. The permittivity, on the other hand, was almost constant. With the evaporation of water, the permittivity decreased, although the conductivities remained constant. Experimental results proved that dielectric properties are affected by environmental conditions, and that it is inevitably necessary to adjust the dielectric properties regularly, through the addition of ingredients, in order to follow the standards. The SAR values, however, were not affected significantly by the change in dielectric properties; thus, a larger tolerance of the dielectric properties may be acceptable in practical SAR measurements.
引用
收藏
页码:126 / 129
页数:4
相关论文
共 13 条
[1]  
*AG TECHN, 1992, 12171 AG TECHN
[2]  
Ballen M. Y., 2001, P 23 ANN BIOEL SOC M, V14, P80
[3]  
CHOU CK, 1984, BIOELECTROMAGNETICS, V5, P435, DOI 10.1002/bem.2250050408
[4]   Dependence of electromagnetic energy absorption upon human head tissue composition in the frequency range of 300-3000 MHz [J].
Drossos, Antonios ;
Santomaa, Veli ;
Kuster, Niels .
IEEE Transactions on Microwave Theory and Techniques, 2000, 48 (11 II) :1988-1995
[5]  
FUKUNAGA K, 2002, EMCJ200244 IEICE
[6]   Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz [J].
Gandhi, OP ;
Lazzi, G ;
Furse, CM .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1884-1897
[7]   A CRITICAL-STUDY OF THE OPEN-ENDED COAXIAL LINE SENSOR TECHNIQUE FOR RF AND MICROWAVE COMPLEX PERMITTIVITY MEASUREMENTS [J].
GRANT, JP ;
CLARKE, RN ;
SYMM, GT ;
SPYROU, NM .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (09) :757-770
[8]  
*IEC, 2002, 10649CD IEC
[9]  
*IEEE, 2002, SCC34 IEEE
[10]  
PEYMAN A, 2002, P BIOEL SOC 24 ANN P, V53, P184