Wettability of biodegradable surfaces

被引:39
作者
Vargha-Butler, EI [1 ]
Kiss, E
Lam, CNC
Keresztes, Z
Kálmán, E
Zhang, L
Neumann, AW
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Eotvos Lorand Univ, Dept Colloid Chem, H-1518 Budapest 112, Hungary
[3] Hungarian Acad Sci, Chem Res Ctr, Dept Surface Sci & Corros Res, H-1525 Budapest, Hungary
关键词
DL-poly(lactic acid); DL-poly(lactic/glycolic acid) copolymers; axisymmetric drop shape analysis-profile (ADSA-P); contact angle; surface tension;
D O I
10.1007/s003960100549
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The study of the interfacial characteristics of biodegradable polymers/copolymers is of importance from the point of view of both surface science and pharmaceutical/ cosmetic applications. Films formed from biodegradable polymers allow systematic wettability studies on surfaces with a wide range of copolymer (chemical) compositions. The possibility of interchanging these drug carrier polymers, if their wetting characteristics are similar, could be beneficial to diverse applications. Low-rate dynamic contact angles on films (solvent cast on polar substrates, i.e. on silicon wafer) of poly(lactic acid), and its copolymers with poly(glycolic acid), (with four different copolymer ratios of 85/15, 75/25, 65/35 and 50,150) were measured by axisymmetric drop shape analysis-profile (ADSA-P) with four liquids: water, formamide, 2,2'-thiodiethanol and 3-pyridylcarbinol. The solid surface tensions. gamma(SV), were calculated from the advancing contact angles. 0(A). The surface topography of the polymer films was investigated by atomic force microscopy (AFM). The surface composition of the polymer layers was analyzed by X-ray photoelectron spectroscopy (XPS). The advancing contact angles were found to be independent of the composition of the copolymers, while the receding angles, OR, did decrease with increasing ratio of the polar component [poly(glycolic acid)] in the copolymers. The solid surface tensions calculated from the advancing contact angles of the liquids for all homo- and copolymers were the same within the error limit, the mean value being gamma(SV) = 35.6 +/- 0.2 mJ/m(2) The surface roughness, which was obtained from AFM images, increased with increasing poly(glycolic acid) ratio, without affecting the advancing contact angles. The constancy of gamma(SV) is attributed to the effect of the surface activity of the nonpolar segments of the polymer chains, which oriented to form the outermost layer of the film. This was confirmed by XPS analysis.
引用
收藏
页码:1160 / 1168
页数:9
相关论文
共 43 条
[1]  
Allemann E, 1996, INT J CANCER, V66, P821, DOI 10.1002/(SICI)1097-0215(19960611)66:6<821::AID-IJC19>3.0.CO
[2]  
2-5
[3]  
[Anonymous], 1996, APPL SURFACE THERMOD
[4]   Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[5]  
Beamson G, 1992, SCIENTA ESCA300 DATA
[6]   PREPARATION AND CHARACTERIZATION OF 5-FLUOROURACIL-LOADED MICROPARTICLES AS BIODEGRADABLE ANTICANCER DRUG CARRIERS [J].
BOISDRONCELLE, M ;
MENEI, P ;
BENOIT, JP .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1995, 47 (02) :108-114
[7]  
Brannon-Peppas L., 1997, MEDICAL PLASTICS BIO, P1
[8]  
BUDZIAK CJ, 1992, THESIS U TORONTO CAN
[9]   AUTOMATION OF AXISYMMETRIC DROP SHAPE-ANALYSIS FOR MEASUREMENT OF INTERFACIAL-TENSIONS AND CONTACT ANGLES [J].
CHENG, P ;
LI, D ;
BORUVKA, L ;
ROTENBERG, Y ;
NEUMANN, AW .
COLLOIDS AND SURFACES, 1990, 43 (2-4) :151-167
[10]  
CHENG P, 1990, THESIS U TORONTO CAN