Removal of heavy metal ions by superconducting magnetic separation

被引:11
作者
Gillet, G
Diot, F
Lenoir, M
机构
[1] INPL, ENSG, Lab Environm & Mineralurg, CNRS,UMR 7569, F-54501 Vandoeuvre Nancy, France
[2] Ste Raoul Lenoir Zone Ind Bearn, F-54403 Longwy, France
关键词
D O I
10.1081/SS-100100753
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Several industrial sectors such as surface treatment, petroleum, chemical, etc. generate effluents containing heavy metal ions (HMI). The main metal ions in such effluents can be zinc, copper, vanadium, etc. Purification of such effluents by magnetic separation is performed by adding a certain proportion of iron salts. These salts precipitates together with those of HMI by increasing the pH. The coprecipitation of this "magnetic carrier" with heavy metals hydroxydes to create a magnetic flee has been studied. The effluent treated passes by a superconducting separator where the flocs are retained in a matrix of steel wires. The purified effluent leaves the separator, and the trapped flocs are collected when the matrix is saturated. The efficiency of HMI separation by this method exceeds 95%.
引用
收藏
页码:2023 / 2037
页数:15
相关论文
共 13 条
[1]  
BUREAU V, 1993, THESIS INPL
[2]  
GILLET G, 1994, P C INT RECH SOUS PR
[3]  
GILLET G, 1996, MINES CARRIERES TECH, V1, P4
[4]  
GILLET G, 1994, CRYOMAGNETIC SEPARAT
[5]  
GILLET G, 1991, TECHNIQUES INGENIEUR, pA5220
[6]  
GILLET G, 1992, MINES CARRIERES TECH, P51
[7]  
Kopp J, 1991, MAGNETIC ELECT SEPAR, V3, P17
[8]  
OKUDA T, 1975, FILTR SEP SEP, P472
[9]  
RICHARDS D, 1997, P IMPC AACH 21 26 SE, P639
[10]  
SVOBODA J, 1987, MINERAL PROCESSING, V8