Characterization of an insoluble polyimide oligomer by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:58
作者
Gies, AP
Nonidez, WK [1 ]
Anthamatten, M
Cook, RC
Mays, JW
机构
[1] Univ Alabama Birmingham, Dept Chem, Birmingham, AL 35294 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[3] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[4] Oak Ridge Natl Lab, Chem Sci Div, Oak Ridge, TN 37831 USA
关键词
D O I
10.1002/rcm.809
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the past two years, papers have appeared in the literature which demonstrate that matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra can be obtained from matrix-analyte preparations which have been produced by grinding the two materials together until a powder of small particle size is obtained. In the present study that methodology was modified and applied to an insoluble polyimide oligomer, poly(4,4'-oxydiphenylenepyromellitimide) (POPM). Two matrix materials were employed in this analysis, 1,8 dihydroxyanthrone (dithranol) and 3-aminoquinoline, with and without an additional cationizing agent. The spectra obtained by this method are shown to be sensitive to the matrix employed in the analysis as well as the quantity of cationizing agent combined with the matrix. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1903 / 1910
页数:8
相关论文
共 18 条
[1]  
Bruch M, 1999, J POLYM SCI POL CHEM, V37, P3367
[2]  
COTTS P, 1992, J POLYM SCI POL LETT, V80, P373
[3]   Mass spectrometry of polymers and polymer surfaces [J].
Hanton, SD .
CHEMICAL REVIEWS, 2001, 101 (02) :527-569
[4]   APPARATUS FOR CHEMICAL-VAPOR-DEPOSITION OF POLYIMIDE FILMS [J].
HUTCHINGS, CW ;
GRUNZE, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (07) :3943-3947
[5]  
Kassis CM, 1997, RAPID COMMUN MASS SP, V11, P1462
[6]   ONLINE MEASUREMENT OF THE RMS RADIUS OF GYRATION AND MOLECULAR-WEIGHT OF POLYIMIDE PRECURSOR FRACTIONS ELUTING FROM A SIZE-EXCLUSION CHROMATOGRAPH [J].
KIM, S ;
COTTS, PM ;
VOLKSEN, W .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1992, 30 (02) :177-183
[7]   Vapor-deposited polyimide ablators for NIF: Effects of deposition process parameters and solvent vapor smoothing on capsule surface finish [J].
Letts, SA ;
Nissen, AEH ;
Orthion, PJ ;
Buckley, SR ;
Fearon, E ;
Chancellor, C ;
Roberts, CC ;
Parrish, BK ;
Cook, RC .
FUSION SCIENCE AND TECHNOLOGY, 2002, 41 (03) :268-277
[8]  
Nielen MWF, 1999, MASS SPECTROM REV, V18, P309, DOI 10.1002/(SICI)1098-2787(1999)18:5<309::AID-MAS2>3.0.CO
[9]  
2-L
[10]   MALDI-TOF mass spectrometry of insoluble giant polycyclic aromatic hydrocarbons by a new method of sample preparation [J].
Przybilla, L ;
Brand, JD ;
Yoshimura, K ;
Räder, HJ ;
Müllen, K .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4591-4597