Two-step solvent extraction flow injection system for the determination of anionic surfactants by spectrophotometry

被引:10
作者
Fan, SH [1 ]
Fang, ZL [1 ]
机构
[1] ACAD SINICA,INST APPL ECOL,FLOW INJECT ANAL RES CTR,SHENYANG 110015,PEOPLES R CHINA
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 04期
基金
中国国家自然科学基金;
关键词
Methylene Blue; Anionic Surfactant; Flow Injection System; Conical Cavity; Sodium Dodecyl Sulfon;
D O I
10.1007/s002160050181
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated how injection procedure for the determination of anionic surfactants with two-step extraction was developed, based on the official methylene blue method. A washing step was used for on-line treatment of the extracted products with methylene blue to eliminate interferences. An improved gravitational phase separator was used to overcome the limitations of the membrane separator, and an effective separation of the two phases was performed by gravity separation in a conical cavity constructed of PTFE and stainless steel. Use of PTFE pump tubing allowed reliable and reproducible withdrawal and propulsion of organic extractant at low how-rates. The calibration graphs were linear up to 6.0 mg/l of sodium dodecyl sulfonate in aqueous solution when 100 mu l of sample was injected, a relative standard deviation of 4.6% (n = 7) was achieved. The recoveries of the procedure were in the range of 89-107%. The results obtained for anionic surfactants in waste water samples agreed well with those obtained by the standard methylene blue batch method.
引用
收藏
页码:416 / 419
页数:4
相关论文
共 14 条
[1]   INDIRECT ATOMIC-ABSORPTION DETERMINATION OF ANIONIC SURFACTANTS IN WASTEWATERS BY FLOW-INJECTION CONTINUOUS LIQUID-LIQUID-EXTRACTION [J].
GALLEGO, M ;
SILVA, M ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2265-2269
[2]  
HEIN H, 1992, WATER ENV ANAL UV VI
[3]  
HIGUCHI K, 1980, BUNSEKI KAGAKU, V29, P180
[4]   SPECTROPHOTOMETRIC DETERMINATION OF ANIONIC SURFACTANTS IN RIVER WATERS USING 1-(4-NITROBENZYL)-4-(4-DIETHYLAMINOPHENYLAZO)-PYRIDINIUM BROMIDE [J].
HIGUCHI, K ;
SHIMOISHI, Y ;
MIYATA, H ;
TOEI, K ;
HAYAMI, T .
ANALYST, 1980, 105 (1253) :768-773
[5]  
*JAP IND STAND COM, 1974, 0102 JISK
[6]   DETERMINATION OF ANIONIC SURFACTANTS BY FLOW INJECTION ANALYSIS BASED ON ION-PAIR EXTRACTION [J].
KAWASE, J ;
NAKAE, A ;
YAMANAKA, M .
ANALYTICAL CHEMISTRY, 1979, 51 (11) :1640-1643
[7]  
LOGWELL J, 1955, ANALYST, V80, P167
[8]   SOLVENT-EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF ANIONIC SURFACTANTS WITH ETHYL VIOLET [J].
MOTOMIZU, S ;
FUJIWARA, S ;
FUJIWARA, A ;
TOEL, K .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :392-397
[9]   SPECTROPHOTOMETRIC DETERMINATION OF ANIONIC SURFACTANTS IN WATER AFTER SOLVENT-EXTRACTION COUPLED WITH FLOW-INJECTION [J].
MOTOMIZU, S ;
OSHIMA, M ;
KURODA, T .
ANALYST, 1988, 113 (05) :747-753
[10]  
MOTOMIZU S, 1987, ANAL SCI, V3, P265