Automated microanalysis using magnetic beads with commercial capillary electrophoretic instrumentation

被引:69
作者
Rashkovetsky, LG [1 ]
Lyubarskaya, YV [1 ]
Foret, F [1 ]
Hughes, DE [1 ]
Karger, BL [1 ]
机构
[1] NORTHEASTERN UNIV,BARNETT INST,BOSTON,MA 02115
关键词
magnetic beads; enzymatic analysis; immunoassays; enzymes; antigens;
D O I
10.1016/S0021-9673(97)00629-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of a new microanalytical method using magnetic beads (MBs) and commercial capillary electrophoresis (CE) instrumentation for performing enzymatic and inhibition assays, as well as for analysis of biological molecules such as antigens, substrates, etc., has been explored. A small quantity of magnetic beads containing immobilized biomolecules was injected into a neutral hydrophilic-coated fused-silica capillary. The short plug (2-3 mm) of beads was held fixed by a magnet placed in the cartridge of the CE system, without the use of frits. The beads could be replaced after each run, eliminating the need to regenerate the solid support. Two protocols were used for analysis: sequential injection (SI) and SI followed by isotachophoretic (ITP) focusing. Alkaline phosphatase (AP) and HIV-protease were used to demonstrate the SI procedure for enzymatic and inhibition assays. The second protocol, SI/ITP, was employed to quantitate an antigen (mouse mAB) using antibodies (sheep IgG towards mouse AB) immobilized on the beads. The MB-CE method, requiring only femtomole (fmol) quantities of material, can potentially be employed in diagnostic and forensic assays, kinetic studies and searching for inhibitors, ligands, receptors, etc. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 17 条
[1]   TRYPSIN-MODIFIED FUSED-SILICA CAPILLARY MICROREACTOR FOR PEPTIDE-MAPPING BY CAPILLARY ZONE ELECTROPHORESIS [J].
AMANKWA, LN ;
KUHR, WG .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1610-1613
[2]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[3]   INTESTINAL ALKALINE-PHOSPHATASE - CATALYTIC PROPERTIES AND HALF OF SITES REACTIVITY [J].
CHAPPELE.D ;
FOSSET, M ;
IWATSUBO, M ;
GACHE, C ;
LAZDUNSKI, M .
BIOCHEMISTRY, 1974, 13 (09) :1788-1795
[4]  
Dittmann MM, 1995, LC GC-MAG SEP SCI, V13, P800
[5]   CAPILLARY ELECTROPHORESIS, COMBINED WITH AN ONLINE MICRO POSTCOLUMN ENZYME ASSAY [J].
EMMER, A ;
ROERAADE, J .
JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (02) :375-381
[6]  
GOETZINGER W, 1996, Patent No. 23220
[7]   THE USE OF A CONCENTRATION STEP TO COLLECT URINARY COMPONENTS SEPARATED BY CAPILLARY ELECTROPHORESIS AND FURTHER CHARACTERIZATION OF COLLECTED ANALYTES BY MASS-SPECTROMETRY [J].
GUZMAN, NA ;
TREBILCOCK, MA ;
ADVIS, JP .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (05) :997-1015
[8]   MATHEMATICAL TREATMENT OF ELECTROPHORETICALLY MEDIATED MICROANALYSIS [J].
HARMON, BJ ;
PATTERSON, DH ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2655-2662
[9]   APPLICATION OF MAGNETIC BEADS IN BIOASSAYS [J].
HAUKANES, BI ;
KVAM, C .
BIO-TECHNOLOGY, 1993, 11 (01) :60-63
[10]   ELECTROCHEMICAL ENZYME-IMMUNOASSAY USING SEQUENTIAL SATURATION TECHNIQUE IN A 20-MUL CAPILLARY - DIGOXIN AS A MODEL ANALYTE [J].
KANEKI, N ;
XU, Y ;
KUMARI, A ;
HALSALL, HB ;
HEINEMAN, WR ;
KISSINGER, PT .
ANALYTICA CHIMICA ACTA, 1994, 287 (03) :253-258