In vitro evaluation of the bond strength between various ceramics and cobalt-chromium alloy fabricated by selective laser sintering

被引:16
作者
Bae, Eun-Jeong [1 ]
Kim, Hae-Young [1 ]
Kim, Woong-Chui [1 ]
Kim, Ji-Hwan [1 ]
机构
[1] Korea Univ, Dept Dent Lab Sci & Engn, Seoul 02841, South Korea
关键词
Rapid prototyping; Selective Laser Sintering; Dental technique; Bond strength; Coefficient of thermal expansion; MECHANICAL-PROPERTIES; PORCELAIN; TITANIUM; SYSTEM;
D O I
10.4047/jap.2015.7.4.312
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
PURPOSE. This study aimed to present the clinical applicability of restorations fabricated by a new method, by comparing the bond strength of between ceramic powder with different coefficient of thermal expansion and alloys fabricated by Selective laser sintering (SLS). MATERIALS AND METHODS. Fifty Co-Cr alloy specimens (25.0 x 3.0 x 0.5 mm) were prepared by SLS and fired with the ceramic (8.0 x 3.0 x 0.5 mm) (ISO 9693:1999). For comparison, ceramics with different coefficient of thermal expansion were used. The bond strength was measured by three-point bending testing and surfaces were observed with FE-SEM. Results were analyzed with a one-way ANOVA (alpha=.05). RESULTS. The mean values of Duceram Kiss (61.18 +/- 6.86 MPa), Vita VM13 (60.30 +/- 7.14 MPa), Ceramco 3 (58.87 +/- 5.33 MPa), Noritake EX-3 (55.86 +/- 7.53 MPa), and Vintage MP (55.15 +/- 7.53 MPa) were found. No significant difference was observed between the bond strengths of the various metal-ceramics. The surfaces of the specimens possessed minute gaps between the additive manufactured layers. CONCLUSION. All the five powders have bond strengths higher than the required 25 MPa minimum (ISO 9693); therefore, various powders can be applied to metal structures fabricated by SLS.
引用
收藏
页码:312 / 316
页数:5
相关论文
共 25 条
[1]
Al-Amri MD, 2012, KING SAUD U J DENT S, V3, P41
[2]
[Anonymous], RESTORATIVE DENT MAT
[3]
[Anonymous], 1999, 9693 ISO
[4]
Bae EJ, 2014, J ADV PROSTHODONT, V6, P266
[5]
CERAMIC MATERIALS FOR PORCELAIN VENEERS: PART II. EFFECT OF MATERIAL, SHADE, AND THICKNESS ON TRANSLUCENCY [J].
Barizon, Karine T. L. ;
Bergeron, Cathia ;
Vargas, Marcos A. ;
Qian, Fang ;
Cobb, Deborah S. ;
Gratton, David G. ;
Geraldeli, Saulo .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (04) :864-870
[6]
Shear bond strengths of a ceramic system to alternative metal alloys [J].
de Melo, RM ;
Travassos, AC ;
Neisser, MP .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01) :64-69
[7]
Deckard Carl R., U.S. Patent, Patent No. [5155324, 4863538, 4,863,538]
[8]
PORCELAIN-FUSED-TO-METAL (PFM) ALTERNATIVES [J].
Donovan, Terry E. ;
Swift, Edward J., Jr. .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2009, 21 (01) :4-6
[9]
e-Manufacturing Solutions, 2011, INSTR US EOS COB CHR
[10]
Feygin M., 1994, U. S. Patent, Patent No. [5,354,414, 5354414]