Preclinical evaluation of a poly (vinyl alcohol) hydrogel implant as a replacement for the nucleus pulposus

被引:118
作者
Allen, MJ
Schoonmaker, JE
Bauer, TW
Williams, PF
Higham, PA
Yuan, HA
机构
[1] SUNY Upstate Med Ctr, Dept Orthoped Surg, Syracuse, NY 13210 USA
[2] Cleveland Clin Fdn, Dept Orthoped Surg, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Anat Pathol, Cleveland, OH 44195 USA
[4] Stryker Orthpaed, Adv Technol Grp, Mahwah, NJ USA
关键词
artificial nucleus; implant; biocompatibility; intervertebral disc;
D O I
10.1097/01.BRS.0000113871.67305.38
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vivo investigation into the safety of a novel hydrogel implant designed to replace the diseased nucleus pulposus. Objectives. To determine the local and systemic safety of this new implant in a nonhuman primate model. Summary of Background Data. A poly (vinyl alcohol) (PVA) hydrogel has been developed as a prosthetic replacement for the diseased nucleus pulposus. Methods. PVA implants were inserted into discectomy defects created in the L3-L4 or L4-L5 intervertebral disc in 20 male baboons. Empty discectomy defects served as a surgical control in 8 additional animals. Routine follow-up evaluations included radiography, magnetic resonance imaging, gross pathology, and histopathology of both local and remote tissues. Results. Insertion of the PVA hydrogel from an anterior direction produced extrusions in 5 animals from the first series of 15 surgeries (33%). A modified surgical technique, involving an anterolateral rather than anterior approach, was used in 5 animals, but the extrusion rate remained high (20%). Despite these surgical complications, the PVA implants were well tolerated over 24 months in vivo, with no evidence of device-related pathology in the adjacent disc tissue, spinal cord, or remote tissues. Conclusion. Implantation of the PVA implant for periods of up to 24 months produced no evidence of local or systemic toxicity. Additional studies are now needed to determine the efficacy of the device in its intended application.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 19 条
[1]   Identification of orthopaedic wear debris [J].
Bauer, TW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (04) :479-481
[2]  
Boelens JJ, 2000, J BIOMED MATER RES, V50, P546, DOI 10.1002/(SICI)1097-4636(20000615)50:4<546::AID-JBM10>3.0.CO
[3]  
2-Y
[4]  
CRISCITIELLO AA, 1999, 14 ANN M N AM SPIN S
[5]   MORPHOLOGY AND KINEMATICS OF THE BABOON UPPER CERVICAL-SPINE - A MODEL OF THE ATLANTOAXIAL COMPLEX [J].
DICKMAN, CA ;
CRAWFORD, NR ;
TOMINAGA, T ;
BRANTLEY, AGU ;
COONS, S ;
SONNTAG, VKH .
SPINE, 1994, 19 (22) :2518-2523
[6]   CIDEX-INDUCED SYNOVITIS [J].
HARNER, CD ;
FU, FH ;
MASON, GC ;
WISSINGER, HA ;
RABIN, BS .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (01) :96-102
[7]   Isolation and quantitation of debris particles around failed silicone orthopedic implants [J].
Hirakawa, K ;
Bauer, TW ;
Culver, JE ;
Wilde, AH .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (05) :819-827
[8]   Anatomy of soft tissues of the spinal canal [J].
Hogan, Q ;
Toth, J .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 1999, 24 (04) :303-310
[9]  
HUKINS S, 1988, BIOL INTERVERTEBRAL
[10]  
KITANO T, 1993, CLIN ORTHOP RELAT R, P372