Monitoring Intrathoracic Impedance with an Implantable Defibrillator Reduces Hospitalizations in Patients with Heart Failure

被引:98
作者
Catanzariti, Domenico [1 ]
Lunati, Maurizio [2 ]
Landolina, Maurizio [3 ]
Zanotto, Gabriele [4 ]
Lonardi, Gabriele [5 ]
Iacopino, Saverio
Oliva, Fabrizio [2 ]
Perego, Giovanni B. [6 ]
Varbaro, Annamaria [7 ]
Denaro, Alessandra [7 ]
Valsecchi, Sergio [7 ]
Vergara, Giuseppe [1 ]
机构
[1] Osped Santa Maria del Carmine, Rovereto, Italy
[2] Osped Niguarda Ca Granda, Milan, Italy
[3] IRCCS, Fdn Policlin S Matteo, Pavia, Italy
[4] Osped Civile Maggiore Borgo Trento, Verona, Italy
[5] Osped Mater Salutis, Legnago, Italy
[6] Ist Auxol S Luca, Milan, Italy
[7] Medtron Italia, Rome, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 03期
关键词
heart failure; hospitalization; intrathoracic impedance; implantable defibrillator; CARDIAC-RESYNCHRONIZATION; DIAGNOSIS; MORBIDITY; MORTALITY; TRIAL;
D O I
10.1111/j.1540-8159.2008.02245.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Some implantable cardioverter-defibrillators (ICDs) are now able to monitor intrathoracic impedance. The aim of the study was to describe the use of such monitoring in clinical practice and to evaluate the clinical impact of the fluid accumulation alert feature of these ICDs. Methods and Results: Five hundred thirty-two heart failure (HF) patients implanted with these ICDs were followed up for 11 +/- 7 months. A clinical event (CE) was deemed to have occurred if it resulted in hospitalization or milder manifestations of HF deterioration. Three hundred sixty-two acute decreases in intrathoracic impedance (Z events) occurred in 230 patients. Of these episodes, 171 (47%) were associated with a CE within 2 weeks of the Z event. In another 71 (20%) Z events, drug therapy was adjusted despite the absence of overt signs of clinical deterioration. The rate of unexplained Z events was 0.25 per patient-year and 25 hospitalizations were not associated with Z events. The audible alert was disabled in a group of 102 patients (OFF group). HF hospitalizations occurred in 29 (7%) patients in the ON group and 20 (20%, P < 0.001) patients in the OFF group. The rate of combined cardiac death and HF hospitalization was lower in patients with Alert ON (log-rank test, P = 0.007). Conclusions: The ICD reliably detected CE and yielded low rates of unexplained and undetected events. The alert capability seemed to reduce the number of HF hospitalizations by allowing timely detection and therapeutic intervention. (PACE 2009; 32:363-370).
引用
收藏
页码:363 / 370
页数:8
相关论文
共 20 条
[1]   Continuous autonomic assessment in patients with symptomatic heart failure - Prognostic value of heart rate variability measured by an implanted cardiac resynchronization device [J].
Adamson, PB ;
Smith, AL ;
Abraham, WT ;
Kleckner, KJ ;
Stadler, RW ;
Shih, A ;
Rhodes, MM .
CIRCULATION, 2004, 110 (16) :2389-2394
[2]   Ongoing right ventricular hemodynarnics in heart failure -: Clinical value of measurements derived from an implantable monitoring system [J].
Adamson, PB ;
Magalski, A ;
Braunschweig, F ;
Böhm, M ;
Reynolds, D ;
Steinhaus, D ;
Luby, A ;
Linde, C ;
Ryden, L ;
Cremers, B ;
Takle, T ;
Bennett, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (04) :565-571
[3]   Self-care behaviors among patients with heart failure [J].
Artinian, NT ;
Magnan, M ;
Sloan, M ;
Lange, MP .
HEART & LUNG, 2002, 31 (03) :161-172
[4]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[5]   Can monitoring of intrathoracic impedance reduce morbidity and mortality in patients with chronic heart failure? Rationale and design of the Diagnostic Outcome Trial in Heart Failure (DOT-HF) [J].
Braunschweig, Frieder ;
Ford, Ian ;
Conraads, Viviane ;
Cowie, Martin R. ;
Jondeau, Guillaume ;
Kautzner, Josef ;
Lunati, Maurizio ;
Aguilera, Roberto Munoz ;
Yu, Cheuk Man ;
Marijianowskii, Monique ;
Borggrefe, Martin ;
van Veldhuisen, Dirk J. .
EUROPEAN JOURNAL OF HEART FAILURE, 2008, 10 (09) :907-916
[6]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[7]   Determinants of successful telemedicine implementations: a literature study [J].
Broens, Tom H. F. ;
in't Veld, Rianne M. H. A. Huis ;
Vollenbroek-Hutten, Miriam M. R. ;
Hermens, Hermie J. ;
van Halteren, Aart T. ;
Nieuwenhuis, Lambert J. M. .
JOURNAL OF TELEMEDICINE AND TELECARE, 2007, 13 (06) :303-309
[8]   Telemonitoring for patients with chronic heart failure: A systematic review [J].
Chaudhry, Sarwat I. ;
Phillips, Christopher O. ;
Stewart, Simon S. ;
Riegel, Barbara ;
Mattera, Jennifer A. ;
Jerant, Anthony F. ;
Krumholz, Harlan M. .
JOURNAL OF CARDIAC FAILURE, 2007, 13 (01) :56-62
[9]   Telemonitoring or structured telephone support programmes for patients with chronic heart failure: systematic review and meta-analysis [J].
Clark, Robyn A. ;
Inglis, Sally C. ;
McAlister, Finlay A. ;
Cleland, John G. F. ;
Stewart, Simon .
BMJ-BRITISH MEDICAL JOURNAL, 2007, 334 (7600) :942-945
[10]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549