Biological/biomedical accelerator mass spectrometry targets.: 1.: Optimizing the CO2 reduction step using zinc dust

被引:21
作者
Kim, Seung-Hyun [1 ]
Kelly, Peter B. [2 ]
Clifford, Andrew J. [1 ]
机构
[1] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Chem, Davis, CA 95616 USA
关键词
D O I
10.1021/ac801226g
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Biological and biomedical applications of accelerator mass spectrometry (AMS) use isotope ratio mass spectrometry to quantify minute amounts of long-lived radioisotopes such as C-14. AMS target preparation involves first the oxidation of carbon (in sample of interest) to CO2 and second the reduction of CO2 to filamentous, fluffy, fuzzy, or firm graphite-like substances that coat a -400-mesh spherical iron powder (-400MSIP) catalyst. Until now, the quality of AMS targets has been variable; consequently, they often failed to produce robust ion currents that are required for reliable, accurate, precise, and high-throughput AMS for biological/biomedical applications. Therefore, we described our optimized method for reduction of CO2 to high-quality uniform AMS targets whose morphology we visualized using scanning electron microscope pictures. Key features of our optimized method were to reduce CO2 (from a sample of interest that provided 1 mg of C) using 100 +/- 1.3 mg of Zn dust, 5 +/- 0.4 mg of -400MSIP, and a reduction temperature of 500 degrees C for 3 h. The thermodynamics of our optimized method were more favorable for production of graphite-coated iron powders (GCIP) than those of previous methods. All AMS targets from our optimized method were of 100% GCIP, the graphitization yield exceeded 90%, and delta C-13 was -17.9 +/- 0.3 parts per thousand. The GCIP reliably produced strong C-12(-) currents and accurate and precise F-m values. The observed F-m value for oxalic acid II NIST SRM deviated from its accepted F-m value of 1.3407 by only 0.0003 +/- 0.0027 (mean +/- SE, n = 32), limit of detection of C-14 was 0.04 amol, and limit of quantification was 0.07 amol, and a skilled analyst can prepare as many as 270 AMS targets per day. More information on the physical (hardness/color), morphological (SEMs), and structural (FT-IR, Raman, XRD spectra) characteristics of our AMS targets that determine accurate, precise, and high-hroughput AMS measurement are in the companion paper.
引用
收藏
页码:7651 / 7660
页数:10
相关论文
共 37 条
[1]
TARGET PREPARATION FOR MILLIGRAM SIZED C-14 SAMPLES AND DATA EVALUATION FOR AMS MEASUREMENTS [J].
ANDREE, M ;
BEER, J ;
OESCHGER, H ;
BONANI, G ;
HOFMANN, HJ ;
MORENZONI, E ;
NESSI, M ;
SUTER, M ;
WOLFLI, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 5 (02) :274-279
[2]
[Anonymous], ICRP PUBLICATION
[3]
BEUKENS RP, 1981, S ACCELERATOR MASS S, V416, P425
[4]
Chang R., 2004, Physical Chemistry for Biosciences
[5]
A feasibility study quantifying in vivo human α-tocopherol metabolism [J].
Clifford, Andrew J. ;
de Moura, Fabiana F. ;
Ho, Charlene C. ;
Chuang, Jennifer C. ;
Follett, Jennifer ;
Fadel, James G. ;
Novotny, Janet A. .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2006, 84 (06) :1430-1441
[6]
Sample preparation and blank values at the AMS radiocarbon facility of the University of Lecce [J].
D'Elia, M ;
Calcagnile, L ;
Quarta, G ;
Sanapo, C ;
Laudisa, M ;
Toma, U ;
Rizzo, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 223 :278-283
[7]
Refinement of graphite target production at ORAU [J].
Dee, M ;
Ramsey, CB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 172 :449-453
[8]
ISOTOPE-RATIO AND BACKGROUND CORRECTIONS FOR ACCELERATOR MASS-SPECTROMETRY RADIOCARBON MEASUREMENTS [J].
DONAHUE, DJ ;
LINICK, TW ;
JULL, AJT .
RADIOCARBON, 1990, 32 (02) :135-142
[9]
ACCELERATOR MASS-SPECTROMETRY IN THE BIO-MEDICAL SCIENCES - APPLICATIONS IN LOW-EXPOSURE BIO-MEDICAL AND ENVIRONMENTAL DOSIMETRY [J].
FELTON, JS ;
TURTELTAUB, KW ;
VOGEL, JS ;
BALHORN, R ;
GLEDHILL, BL ;
SOUTHON, JR ;
CAFFEE, MW ;
FINKEL, RC ;
NELSON, DE ;
PROCTOR, ID ;
DAVIS, JC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 52 (3-4) :517-523
[10]
How to convert biological carbon into graphite for AMS [J].
Getachew, Girma ;
Kim, Seung-Hyun ;
Burri, Betty J. ;
Kelly, Peter B. ;
Haack, Kurt W. ;
Ognibene, Ted J. ;
Buchholz, Bruce A. ;
Vogel, John S. ;
Modrow, Jonathan ;
Clifford, Andrew J. .
RADIOCARBON, 2006, 48 (03) :325-336