Determining affinity-selected ligands and estimating binding affinities by online size exclusion chromatography liquid chromatography-mass spectrometry

被引:42
作者
Blom, KF
Larsen, BS
McEwen, CN
机构
[1] Dupont Merck Pharmaceut Co, Res & Dev, Expt Stn, Wilmington, DE 19880 USA
[2] Dupont Co, Cent Res & Dev, Expt Stn, Wilmington, DE 19880 USA
来源
JOURNAL OF COMBINATORIAL CHEMISTRY | 1999年 / 1卷 / 01期
关键词
D O I
10.1021/cc980010k
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Size exclusion chromatography (SEC) isolation of affinity-selected ligands combined with reverse phase liquid chromatography-mass spectrometry (LC-MS) is an effective means for identifying members of mixtures which form tightly bound noncovalent complexes with target proteins. A potential liability of the approach is that the SEC isolation is carried out under nonequilibrium conditions favoring protein/ligand complex dissociation. At long SEC isolation times and/or for complexes with fast off-rates the extent of dissociation can jeopardize the ability to detect the affinity-selected components. Additionally, equilibrium binding affinities cannot be exactly determined from the measured distribution of isolated ligands. We present here an online SEC/LC-MS system for determining affinity-selected members of active mixtures which reduces this liability. A kinetic model of the SEC isolation process is developed to determine the practical limits for the application of the method and to extrapolate equilibrium binding affinities from the nonequilibrium data. The utility of online SEC/LC-MS for identifying affinity-selected ligands and for estimating binding affinities is demonstrated for a small molecule mixture of compounds with known binding affinities and for a simple combinatorial mixture.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 15 条
[1]   BIO-AFFINITY CHARACTERIZATION MASS-SPECTROMETRY [J].
BRUCE, JE ;
ANDERSON, GA ;
CHEN, RD ;
CHENG, XH ;
GALE, DC ;
HOFSTADLER, SA ;
SCHWARTZ, BL ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (08) :644-650
[2]   ESTIMATING K-I VALUES FOR TIGHT-BINDING INHIBITORS FROM DOSE-RESPONSE PLOTS [J].
COPELAND, RA ;
LOMBARDO, D ;
GIANNARAS, J ;
DECICCO, CP .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1995, 5 (17) :1947-1952
[3]  
Dunayevskiy YM, 1997, RAPID COMMUN MASS SP, V11, P1178, DOI 10.1002/(SICI)1097-0231(199707)11:11<1178::AID-RCM991>3.0.CO
[4]  
2-H
[5]  
HEGY G, 1997, P 45 ASMS C MASS SPE, P900
[6]  
HSIEH YF, 1996, MOL DIVERS, V2, P189
[7]   Affinity selection and mass spectrometry-based strategies to identify lead compounds in combinatorial libraries [J].
Kaur, S ;
McGuire, L ;
Tang, DZ ;
Dollinger, G ;
Huebner, V .
JOURNAL OF PROTEIN CHEMISTRY, 1997, 16 (05) :505-511
[8]   Characterization of SH2 - Ligand interactions via library affinity selection with mass spectrometric detection [J].
Kelly, MA ;
Liang, HB ;
Sytwu, II ;
Vlattas, I ;
Lyons, NL ;
Bowen, BR ;
Wennogle, LP .
BIOCHEMISTRY, 1996, 35 (36) :11747-11755
[9]   Characterization of benzodiazepine ''combinatorial'' chemical libraries by on-line immunoaffinity extraction, coupled column HPLC ion spray mass spectrometry tandem mass spectrometry [J].
Nedved, ML ;
HabibiGoudarzi, S ;
Ganem, B ;
Henion, JD .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4228-4236
[10]  
SIEGEL MM, 1997, P 45 ASMS C MASS SPE, P907