Preservation of Viscoelastic Properties of Rabbit Vocal Folds after Implantation of Hyaluronic Acid-Based Biomaterials

被引:17
作者
Choi, Jeong-Seok [1 ]
Kim, Nahn Ju [2 ]
Klemuk, Sarah [3 ]
Jang, Yun Ho [1 ]
Park, In Suh [4 ]
Ahn, Kyung Hyun [2 ]
Lim, Jae-Yol [1 ]
Kim, Young-Mo [1 ]
机构
[1] Inha Univ, Sch Med, Dept Otorhinolaryngol Head & Neck Surg, Inchon 400711, South Korea
[2] Seoul Natl Univ, Sch Chem & Biol Engn, Seoul, South Korea
[3] Univ Iowa, Dept Commun Sci & Disorders, Iowa City, IA USA
[4] Inha Univ, Sch Med, Dept Pathol, Inchon 400711, South Korea
基金
新加坡国家研究基金会;
关键词
viscoelasticity; hyaluronic acid; vocal folds; phonosurgery; PHONATION THRESHOLD PRESSURE; INJECTION AUGMENTATION; SHEAR PROPERTIES; FREQUENCIES; MUCOSA; INSUFFICIENCY; INJECTABLES; SURGERY;
D O I
10.1177/0194599812446913
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 [耳鼻咽喉科学];
摘要
Objectives. To compare the rheological characteristics of structurally different hyaluronic acid (HA)-based biomaterials that are presently used for phonosurgery and to investigate their influence on the viscoelastic properties of vocal folds after implantation in an in vivo rabbit model. Study Design. In vitro and in vivo rheometric investigation. Setting. Experimental laboratory, Inha and Seoul National Universities. Methods. Viscoelastic shear properties of 3 HA-based biomaterials (Rofilan, Restylane, and Reviderm) were measured with a strain-controlled rheometer. These biomaterials were injected into the deep layers of rabbit vocal folds, and viscoelastic moduli of the injected vocal folds were determined 2 months after the injection. The vocal fold specimens were observed using a light microscope and a transmission electron microscope. Results. All HA-based biomaterials showed similar levels of shear viscosity, which were slightly higher than that of human vocal folds reported in previous studies. Compared with noninjected control vocal folds, there were no significant differences in the magnitudes of both elastic shear modulus (G') and viscous modulus (G '') of injected vocal folds among all of the materials. Light microscopic images showed that all materials were observed in the deep layers of vocal folds and electron scanning images revealed that injected HA particles were homogeneously distributed in regions of collagenous fibers. Conclusion. HA-based biomaterials could preserve the viscoelastic properties of the vocal folds, when they were injected into vocal folds in an in vivo rabbit model. However, further studies on the influence of the biomaterials on the viscoelasticity of human vocal folds in ECM surroundings are still needed.
引用
收藏
页码:515 / 521
页数:7
相关论文
共 21 条
[1]
Bird R. B., 1987, FLUID MECH, V1
[2]
Evaluation of injection augmentation treatment of hyaluronic acid based materials on rabbit vocal folds viscoelasticity [J].
Borzacchiello, A ;
Mayol, L ;
Gärskog, O ;
Dahlqvist, Å ;
Ambrosio, L .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (06) :553-557
[3]
A review of dermal fillers in facial plastic surgery [J].
Bray, Dominic ;
Hopkins, Claire ;
Roberts, David N. .
CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2010, 18 (04) :295-302
[4]
Viscoelasticity of hyaluronan and nonhyaluronan based vocal fold injectables: Implications for mucosal versus muscle use [J].
Caton, Trace ;
Thibeault, Susan L. ;
Klemuk, Sarah ;
Smith, Marshall E. .
LARYNGOSCOPE, 2007, 117 (03) :516-521
[5]
A simple-shear rheometer for linear viscoelastic characterization of vocal fold tissues at phonatory frequencies [J].
Chan, Roger W. ;
Rodriguez, Maritza L. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 124 (02) :1207-1219
[6]
Dependence of phonation threshold pressure on vocal tract acoustics and vocal fold tissue mechanics [J].
Chan, RW ;
Titze, IR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (04) :2351-2362
[7]
Viscosities of implantable biomaterials in vocal fold augmentation surgery [J].
Chan, RW ;
Titze, IR .
LARYNGOSCOPE, 1998, 108 (05) :725-731
[8]
Hyaluronic acid (with fibronectin) as a bioimplant for the vocal fold mucosa [J].
Chan, RW ;
Titze, IR .
LARYNGOSCOPE, 1999, 109 (07) :1142-1149
[9]
Viscoelastic shear properties of human vocal fold mucosa: Measurement methodology and empirical results [J].
Chan, RW ;
Titze, IR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (04) :2008-2021
[10]
The importance of hyaluronic acid in vocal fold biomechanics [J].
Chan, RW ;
Gray, SD ;
Titze, IR .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2001, 124 (06) :607-614