Compressive mechanical properties of the intraluminal thrombus in abdominal aortic aneurysms and fibrin-based thrombus mimics

被引:45
作者
Ashton, John H. [2 ]
Geest, Jonathan P. Vande [1 ,2 ,3 ]
Simon, Bruce R. [1 ,2 ]
Haskett, Darren G. [4 ]
机构
[1] Univ Arizona, Dept Aerosp & Mech Engn, Soft Tissue Biomech Lab, Tucson, AZ 85721 USA
[2] Univ Arizona, Biomed Engn Interdisciplinary Program, Tucson, AZ 85721 USA
[3] Univ Arizona, BIO5 Inst, Tucson, AZ 85721 USA
[4] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
关键词
Aneurysm; Intraluminal thrombus; AAA; Compressive modulus; Fibrinogen; CROSSLINKING; ELASTICITY; MODULUS; CALCIUM; MODEL;
D O I
10.1016/j.jbiomech.2008.10.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
An intraluminal thrombus (ILT) forms in the majority of abdominal aortic aneurysms (AAAs). While the ILT has traditionally been perceived as a byproduct of aneurysmal disease, the mechanical environment within the ILT may contribute to the degeneration of the aortic wall by affecting biological events of cells embedded within the ILT. In this study, the drained secant modulus (E-5 similar to modulus at 5% strain) of ILT specimens (luminal, medial, and abluminal) procured from elective open repair was measured and compared using unconfined compression. Five groups of fibrin-based thrombus mimics were also synthesized by mixing various combinations of fibrinogen, thrombin, and calcium. Drained secant moduli were compared to determine the effect of the components' concentrations on mimic stiffness. The stiffness of mimics was also compared to the native ILT. Preliminary data on the water content of the ILT layers and mimics was measured. It was found that the abluminal layer (E-5 = 19.3 kPa) is stiffer than the medial (2.49 kPa) and luminal (1.54 kPa) layers, both of which are statistically similar. E-5 of the mimics (0.63, 0.22, 0.23, 0.87, and 2.54 kPa) is dependent on the concentration of all three components: E-5 decreases with a decrease in fibrinogen (60-20 and 20-15 mg/ml) and a decrease in thrombin (3-0.3 units/ml), and E-5 increases with a decrease in calcium (0.1-0.01 M). E-5 from two of the mimics were not statistically different than the medial and luminal layers of ILT. A thrombus mimic with similar biochemical components, structure, and mechanical properties as native ILT would provide an appropriate test medium for AAA mechanobiology studies. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 25 条
[1]
Cellular content and permeability of intraluminal thrombus in abdominal aortic aneurysm [J].
Adolph, R ;
Vorp, DA ;
Steed, DL ;
Webster, MW ;
Kameneva, MV ;
Watkins, SC .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (05) :916-926
[2]
Clinical decision making for endovascular repair of abdominal aortic aneurysm [J].
Al-Omran, M ;
Verma, S ;
Lindsay, TF ;
Weisel, RD ;
Sternbach, Y .
CIRCULATION, 2004, 110 (23) :E517-E523
[3]
New method to prepare autologous fibrin glue on demand [J].
Alston, Steven M. ;
Solen, Kenneth A. ;
Broderick, Adam H. ;
Sukavaneshvar, Sivaprasad ;
Mohammad, S. Fazal .
TRANSLATIONAL RESEARCH, 2007, 149 (04) :187-195
[4]
Localized administration of doxycycline suppresses aortic dilatation in an experimental mouse model of abdominal aortic aneurysm [J].
Bartoli, MA ;
Parodi, FE ;
Chu, J ;
Pagano, MB ;
Mao, DL ;
Baxter, BT ;
Buckley, C ;
Ennis, TL ;
Thompson, RW .
ANNALS OF VASCULAR SURGERY, 2006, 20 (02) :228-236
[5]
FIBRIN GEL STRUCTURE AND CLOTTING TIME [J].
BLOMBACK, B ;
OKADA, M .
THROMBOSIS RESEARCH, 1982, 25 (1-2) :51-70
[6]
BOSCHETTI F, 2007, P ASME 2007 SUMM BIO
[7]
FIBRIN STRUCTURE AND CONCENTRATION ALTER CLOT ELASTIC-MODULUS BUT DO NOT ALTER PLATELET-MEDIATED FORCE DEVELOPMENT [J].
CARR, ME ;
CARR, SL .
BLOOD COAGULATION & FIBRINOLYSIS, 1995, 6 (01) :79-86
[8]
Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: Experimental characterisation and structural static computational analysis [J].
Di Martino, E ;
Mantero, S ;
Inzoli, F ;
Melissano, G ;
Astore, D ;
Chiesa, R ;
Fumero, R .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (04) :290-299
[9]
EFFECTS OF CROSSLINKING ON THE RIGIDITY AND PROTEOLYTIC SUSCEPTIBILITY OF HUMAN FIBRIN CLOTS [J].
GLADNER, JA ;
NOSSAL, R .
THROMBOSIS RESEARCH, 1983, 30 (03) :273-288
[10]
Development of fibrinous thrombus analogue for in-vitro abdominal aortic aneurysm studies [J].
Hinnen, J. W. ;
Rixen, D. J. ;
Koning, O. H. J. ;
van Bockel, J. H. ;
Hamming, J. F. .
JOURNAL OF BIOMECHANICS, 2007, 40 (02) :289-295