Electric field-induced mobilisation of multiphase solution systems based on the nitration of benzene in a micro reactor

被引:33
作者
Doku, GN [1 ]
Haswell, SJ [1 ]
McCreedy, T [1 ]
Greenway, GM [1 ]
机构
[1] Univ Hull, Dept Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
D O I
10.1039/b007585j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the electric field-induced flow characteristics of multiphase solutions in a micro reactor device using the nitration of benzene as a model process. Photolithographic and wet etching techniques were used to fabricate the micro reactor (channels, 200 mum id, 100 mum deep) in a borosilicate glass substrate. The results focus specifically on the flow parameters of reagents/reactants (i.e., voltage, solution concentration and pH ranges and current-voltage relationships) used in this study. The benzene was introduced and mobilised by electroosmotic flow (EOF), as a microemulsion using an appropriate surfactant (sodium dodecyl sulfate), whilst the nitronium ions, produced in situ from mixed H2SO4-HNO3 (the nitrating agent), underwent electrophoretic-induced (electrokinetic) mobility. A co-surfactant, butan-1-ol, was used owing to (a) its relative solubility in the aqueous surfactant solution. (b) its ability to aid the solubilization of benzene, (c) the provision of a water-rich (oil-in-water) rather than oil-rich (water-in-oil) microemulsion system and (d) its lack of significant adverse effects on the EOF. The optimum conditions used for the nitration of benzene within the micro reactor were a run of the microemulsion as main reagent stream, then three 30 s segmented injections of mixed acid, with a 5 s push of the microemulsion into the system after each injection, and then a 60 s stopped-flow reaction time before driving reaction product segments to a collection reservoir.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 23 条
[1]  
ALBRIGHT LF, 1976, IND LAB NITRATIONS, P1
[2]  
BIRD S, 1996, THESIS U HULL
[3]   The fabrication of micro-porous silica structures for micro-reactor technology [J].
Christensen, PD ;
Johnson, SWP ;
McCreedy, T ;
Skelton, V ;
Wilson, NG .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :341-343
[4]   DEVELOPMENT OF A MICRO FLOW-INJECTION MANIFOLD FOR THE DETERMINATION OF ORTHOPHOSPHATE [J].
DAYKIN, RNC ;
HASWELL, SJ .
ANALYTICA CHIMICA ACTA, 1995, 313 (03) :155-159
[5]   Further studies into the development of a micro-FIA (μFIA) system based on electroosmotic flow for the determination of phosphate as orthophosphate [J].
Doku, GN ;
Haswell, SJ .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :1-13
[6]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[7]  
Fletcher P, 1999, CHEM BRIT, V35, P38
[8]   Theoretical considerations of chemical reactions in micro-reactors operating under electroosmotic and electrophoretic control [J].
Fletcher, PDI ;
Haswell, SJ ;
Paunov, VN .
ANALYST, 1999, 124 (09) :1273-1282
[9]   The use of a novel microreactor for high throughput continuous flow organic synthesis [J].
Greenway, GM ;
Haswell, SJ ;
Morgan, DO ;
Skelton, V ;
Styring, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :153-158
[10]   Chemical and biochemical microreactors [J].
Haswell, S ;
Skelton, V .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (06) :389-395