Rapid and accurate U/Th dating using parallel ion-counting multi-collector ICP-MS

被引:232
作者
Hellstrom, J [1 ]
机构
[1] Univ Melbourne, Sch Earth Sci, Melbourne, Vic 3010, Australia
关键词
D O I
10.1039/b308781f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using the parallel ion-counting capability of an appropriately configured multi-collector ICP-MS it is possible to simultaneously measure the activity ratios Th-230/U-234 and U-234/U-238 in a single solution. A method has been developed which fully internalises the measurement of elemental fractionation, instrument mass bias and ion counter gain, allowing on-line calculation of U/Th ages on a cycle-by-cycle basis during data acquisition. Because of the high efficiency of this technique very small sample sizes can be used, with permil-level precision possible on both Th-230/U-238 and U-234/U-238 from analyses of a few tens of nanograms of uranium. As U and Th fractions do not need to be collected and analysed separately sample throughput is very high, using a simple TRU-Spec ion exchange resin procedure. Repeat analyses of Harwell Uraninite, NIST SRM 960 and two carbonate age standards show excellent agreement with results from other laboratories.
引用
收藏
页码:1346 / 1351
页数:6
相关论文
共 20 条
[1]  
[Anonymous], 1999, BERKELEY GEOCHRON CT
[2]   The half-lives of uranium-234 and thorium-230 [J].
Cheng, H ;
Edwards, RL ;
Hoff, J ;
Gallup, CD ;
Richards, DA ;
Asmerom, Y .
CHEMICAL GEOLOGY, 2000, 169 (1-2) :17-33
[3]  
DESMARCHELIER JM, 1999, THESIS AUSTR NATL U
[4]   U-238 U-234-TH-230-TH-232 SYSTEMATICS AND THE PRECISE MEASUREMENT OF TIME OVER THE PAST 500000 YEARS [J].
EDWARDS, RL ;
CHEN, JH ;
WASSERBURG, GJ .
EARTH AND PLANETARY SCIENCE LETTERS, 1987, 81 (2-3) :175-192
[5]  
HELLSTROM J, 2000, J C ABSTR, V5, P506
[6]  
HELLSTROM JC, 1998, THESIS AUSTR NATL U
[7]  
IHLENFELD C, 2003, THESIS LA TROBE U AU
[8]   COMPARISON OF TH230 AND C14 AGES FOR CARBONATE MATERIALS FROM LAKES LAHONTAN AND BONNEVILLE [J].
KAUFMAN, A ;
BROECKER, W .
JOURNAL OF GEOPHYSICAL RESEARCH, 1965, 70 (16) :4039-&
[9]   High precision 230Th/232Th and 234U/238U measurements using energy-filtered ICP magnetic sector multiple collector mass spectrometry [J].
Luo, XZ ;
Rehkamper, M ;
Lee, DC ;
Halliday, AN .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 171 (1-3) :105-117
[10]   Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry [J].
Maréchal, CN ;
Télouk, P ;
Albarède, F .
CHEMICAL GEOLOGY, 1999, 156 (1-4) :251-273