Simulation of wind-driven ventilative cooling systems for an apartment building in Beijing and Shanghai

被引:79
作者
da Graça, GC [1 ]
Chen, Q [1 ]
Glicksman, LR [1 ]
Norford, LK [1 ]
机构
[1] MIT, Dept Architecture, Bldg Technol Program, Cambridge, MA 02139 USA
关键词
natural ventilation; CFD; energy analysis;
D O I
10.1016/S0378-7788(01)00083-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a performance evaluation of two passive cooling strategies, daytime ventilation and night cooling, for a generic, six-story suburban apartment building in Beijing and Shanghai. The investigation uses a coupled, transient simulation approach to model heat transfer and airflow in the apartments. Wind-driven ventilation is simulated using computational fluid dynamics (CFD). Occupant thermal comfort is accessed using Fanger's comfort model. The results show that night cooling is superior to daytime ventilation. Night cooling may replace air-conditioning systems for a significant part of the cooling season in Beijing, but with a high condensation risk. For Shanghai, neither of the two passive cooling strategies can be considered successful. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 18 条
[1]  
ALLOCCA C, 2000, P 21 AIVC ANN C INN
[2]  
[Anonymous], 1993, 7730 ISO
[3]  
ASHRAE, 1997, ASHRAE Handbook SI (Fundamentals)
[4]  
Aynsley R. M., 1988, ASHRAE T, V94, P1661
[5]  
*CHAM LTD, 1998, PHOENICS VERS 3 1
[6]  
Chandra S., 1984, ASHRAE T, V90, P211
[7]  
DAGRACA GC, 1999, THESIS MIT CAMBRIDGE
[8]   VENTILATION MEASUREMENTS AT MODEL SCALE IN A TURBULENT-FLOW [J].
ETHERIDGE, DW ;
NOLAN, JA .
BUILDING AND ENVIRONMENT, 1979, 14 (01) :53-64
[9]  
FRESKOS GO, 1998, ROOMVENT, V1, P483
[10]  
Givoni Baruch, 1994, Passive Low Energy Cooling of Buildings