Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters

被引:237
作者
Kaufhold, M [1 ]
Borner, G [1 ]
Eberhardt, M [1 ]
Speck, J [1 ]
机构
[1] DRESDEN UNIV TECHNOL, INST HIGH VOLTAGE & HIGH CURRENT ENGN, D-8027 DRESDEN, GERMANY
关键词
converter-fed motors; very fast transients; voltage distribution; partial discharge probability; surface charge accumulation; breakdown of interturn insulation;
D O I
10.1109/57.537190
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
PDs occur in the air-filled gaps of enameled wires that are touching. They erode the insulation and consequently lead to an interturn breakdown.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 15 条
[1]  
AUINGER H, 1995, C ETG ESS GERM SEPT
[2]  
BERTH M, 1995, 7857 ISH
[3]  
BJOERKLUND A, 1995, ELECT ELECT INSULATI, P417
[4]  
*BUR CENTR COMM EL, 1985, IEC PUBLICATION 1, V851
[5]  
*BUR CENTR COMM EL, 1985, IEC PUBLICATION 2, V851
[6]  
*BUR CENTR COMM EL, 1985, IEC PUBLICATION 5, V851
[7]  
Dakin T. W., 1974, Electra, P61
[8]  
KAUFHOLD M, 1995, THESIS TU DRESDEN
[9]  
KAUFHOLD M, 1993, 8 INT S HIGH VOLT EN
[10]  
KAUFHOLD M, 1995, C EL INS DIEL PHEN O