RAPID AND PRECISE IN VIVO MEASUREMENT OF HUMAN CORNEAL THICKNESS WITH OPTICAL LOW-COHERENCE REFLECTOMETRY IN NORMAL HUMAN EYES

被引:30
作者
Waelti, Rudolf [1 ]
Boehnke, Matthias [2 ]
Gianotti, Ronald [1 ]
Bonvin, Pascal [1 ]
Ballif, Julien [1 ]
Salathe, Rene Paul [1 ]
机构
[1] Swiss Fed Inst Technol Lausanne, Inst Appl Opt, CH-1015 Lausanne, Switzerland
[2] Univ Bern, Dept Ophthalmol, CH-3010 Bern, Switzerland
关键词
optical distance measurement; optical position measurement; optical low-coherence reflectometry; optical interferometry; corneal pachometry; corneal thickness;
D O I
10.1117/1.429880
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An optical low-coherence reflectometer is used for rapid noncontact measurements of the human corneal thickness in vivo. Thickness measurements on ten volunteers show a standard deviation of 3.4 mu m. The experiments reveal that the optical reflectometer benefits from a 2.5 fold enhancement of the measurement precision and a 2.8 fold reduction in measurement time compared to a standard clinical ultrasonic pachometer. (C) 1998 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 38 条
[1]  
AZEN SP, 1979, INVEST OPHTH VIS SCI, V18, P535
[2]   Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry [J].
Ballif, J ;
Gianotti, R ;
Chavanne, P ;
Walti, R ;
Salathe, RP .
OPTICS LETTERS, 1997, 22 (11) :757-759
[3]  
Bohnke M, 1997, GER J OPHTHALMOL, V5, P338
[4]   HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE [J].
BOUMA, B ;
TEARNEY, GJ ;
BOPPART, SA ;
HEE, MR ;
BREZINSKI, ME ;
FUJIMOTO, JG .
OPTICS LETTERS, 1995, 20 (13) :1486-1488
[5]  
Chavanne Ph., 1994, EUR OPT SOC C APPL O, P399
[6]   A COMPACT OPTICAL-DEVICE FOR EYE-LENGTH MEASUREMENT [J].
CHEN, S ;
WANG, DN ;
GRATTAN, KTV ;
PALMER, AW ;
DICK, GL .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1993, 5 (06) :729-731
[7]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[8]   OPTICAL LOW COHERENCE REFLECTOMETRY WITH 1-BULLET-9 MU-M SPATIAL-RESOLUTION [J].
CLIVAZ, X ;
MARQUISWEIBLE, F ;
SALATHE, RP .
ELECTRONICS LETTERS, 1992, 28 (16) :1553-1555
[9]   HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES [J].
CLIVAZ, X ;
MARQUISWEIBLE, F ;
SALATHE, RP ;
NOVAK, RP ;
GILGEN, HH .
OPTICS LETTERS, 1992, 17 (01) :4-6
[10]   GUIDED-WAVE REFLECTOMETRY WITH MICROMETER RESOLUTION [J].
DANIELSON, BL ;
WHITTENBERG, CD .
APPLIED OPTICS, 1987, 26 (14) :2836-2842