On the parameters affecting the sensitivity of MR measures of pressure with microbubbles

被引:29
作者
Dharmakumar, R [1 ]
Plewes, DB [1 ]
Wright, GA [1 ]
机构
[1] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
magnetic resonance; microbubble contrast agents; pulmonary pressure; T-2; magnetic susceptibility;
D O I
10.1002/mrm.10075
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, it has been suggested that gas encapsulated distensible microbubbles may serve as pressure probes in the MR field through the relationship between bubble size and 1/T-2 or 1/T-2. Currently, in vivo application of this technique is hindered by the ability of T-2 or T-2* to detect pressure changes that are clinically relevant. This work identifies and characterizes, through numerical simulations, the set of parameters which optimize the ability of this technique to detect small pressure changes. Results show that when the bubbles do not interact magnetically, the T-2- and T-2*-based measurements of pressure are strongly influenced by the bubble size at atmospheric pressure, static magnetic field strength, magnitude of the susceptibility difference between the encapsulated gas and plasma, bubble volume fraction, and the refocusing interval. In particular, to detect clinically relevant pressure changes, microbubbles need to be approximately 2-3 mum in radius, distributed at a volume fraction of 0.15%, and have a volumetric magnetic susceptibility difference of at least 34 ppm. Magn Reson Med 47:264-273, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:264 / 273
页数:10
相关论文
共 28 条
[1]  
ABRAGAM A, 1996, PRINCIPLES NUCL MAGN, P97
[2]   Microbubbles as novel pressure-sensitive MR contrast agents [J].
Alexander, AL ;
McCreery, TT ;
Barrette, TR ;
Gmitro, AF ;
Unger, EC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (06) :801-806
[3]   QUANTITATIVE ASSESSMENT OF PULMONARY-HYPERTENSION IN PATIENTS WITH TRICUSPID REGURGITATION USING CONTINUOUS WAVE DOPPLER ULTRASOUND [J].
BERGER, M ;
HAIMOWITZ, A ;
VANTOSH, A ;
BERDOFF, RL ;
GOLDBERG, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :359-365
[4]   Noninvasive measurement of the hydrostatic pressure in a fluid-filled cavity based on the disappearance time of micrometer-sized free gas bubbles [J].
Bouakaz, A ;
Frinking, PJA ;
de Jong, N ;
Bom, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (09) :1407-1415
[5]   MAGNETIC-RESONANCE IMAGING IN PULMONARY ARTERIAL-HYPERTENSION [J].
BOUCHARD, A ;
HIGGINS, CB ;
BYRD, BF ;
AMPARO, EG ;
OSAKI, L ;
AXELROD, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (15) :938-942
[6]   CONDITIONS FOR INITIAL QUASI-LINEAR T(2)(-1) VERSUS TAU FOR CARR-PURCELL-MEIBOOM-GILL NMR WITH DIFFUSION AND SUSCEPTIBILITY DIFFERENCES IN POROUS-MEDIA AND TISSUES [J].
BROWN, RJS ;
FANTAZZINI, P .
PHYSICAL REVIEW B, 1993, 47 (22) :14823-14834
[7]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[8]  
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[9]   NEW NONINVASIVE TECHNIQUE FOR CARDIAC PRESSURE MEASUREMENT - RESONANT SCATTERING OF ULTRASOUND FROM BUBBLES [J].
FAIRBANK, WM ;
SCULLY, MO .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1977, 24 (02) :107-110
[10]   INTERPRETATION OF WATER NUCLEAR MAGNETIC-RESONANCE RELAXATION-TIMES IN HETEROGENEOUS SYSTEMS [J].
GLASEL, JA ;
LEE, KH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1974, 96 (04) :970-978