Thermal inactivation of water-borne pathogenic and indicator bacteria at sub-boiling temperatures

被引:138
作者
Spinks, AT
Dunstan, RH [1 ]
Harrison, T
Coombes, P
Kuczera, G
机构
[1] Univ Newcastle, Sch Environm & Life Sci, Callaghan, NSW 2308, Australia
[2] Univ Newcastle, Sch Engn & Built Environm, Callaghan, NSW 2308, Australia
关键词
D-value; thermal; destruction; hot water; bacteria; resistance;
D O I
10.1016/j.watres.2006.01.032
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of harvested rainwater in domestic hot water systems can result in optimised environmental and economic benefits to urban water cycle management, however, the water quality and health risks of such a scenario have not been adequately investigated. Thermal inactivation analyses were carried out on eight species of non-spore-forming bacteria in a water medium at temperatures relevant to domestic hot water systems (55-65 degrees C), and susceptibilities to heat stress were compared using D-values. The D-value was defined as the time required to reduce a bacterial population by 90% or 1 log reduction. The results found that both tested strains of Enterococcus faecalis were the most heat resistant of the bacteria studied, followed by the pathogens Shigella sonnei biotype A and Escherichia coli O157:H7, and the non-pathogenic E. coli O3:H6. Pseudomonas aeruginosa was found to be less resistant to heat, while Salmonella typhimurium, Serratia marcescens, Klebsiella pneumoniae and Aeromonas hydrophila displayed minimal heat resistance capacities. At 65 degrees C, little thermal resistance was demonstrated by any species, with log reductions in concentration occurring within seconds. The results of this study suggested that the temperature range from SS to 65 degrees C was critical for effective elimination of enteric/ pathogenic bacterial components and supported the thesis that hot water systems should operate at a minimum of 60 degrees C. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1326 / 1332
页数:7
相关论文
共 43 条
[1]  
ARIYANANDA T, 1999, 9 INT RAINW CATCHM S, V9, P91
[2]  
BARRY ME, 2005, MODELLING URBAN WATE
[3]   Development of thermal inactivation models for Salmonella enteritidis and Escherichia coli O157:H7 with temperature, pH and NaCl as controlling factors [J].
Blackburn, CD ;
Curtis, LM ;
Humpheson, L ;
Billon, C ;
McClure, PJ .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1997, 38 (01) :31-44
[4]   rpoS regulation of acid, heat, and salt tolerance in Escherichia coli O157:H7 [J].
Cheville, AM ;
Arnold, KW ;
Buchrieser, C ;
Cheng, CM ;
Kaspar, CW .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (05) :1822-1824
[5]  
Coombes P. J., 2002, URBAN WATER, V4, P307, DOI DOI 10.1016/S1462-0758(02)00028-6
[6]  
Coombes P.J., 2003, AUST J WATER RESOURC, V7, P101
[7]  
Coombes P.J., 2000, Urban Water, V1, P335, DOI DOI 10.1016/S1462-0758(00)00027-3
[8]  
COOMBES PJ, 2002, 2 INT WAT SENS URB D
[9]  
COOMBES PJ, 2005, AUSTR RUNOFF QUALITY
[10]   A NOTE ON THE TEMPERATURE TOLERANCE OF LEGIONELLA [J].
DENNIS, PJ ;
GREEN, D ;
JONES, BPC .
JOURNAL OF APPLIED BACTERIOLOGY, 1984, 56 (02) :349-350