A proposed technique for intraoperative measurement of cervical spine stiffness

被引:15
作者
Frank, E
Chamberland, D
Ragel, B
机构
[1] Division of Neurosurgery, Oregon Health Sciences University, Portland, OR
[2] Division of Neurosurgery, Oregon Health Sciences University, Portland, OR 97201
关键词
intraoperative measurement; load-displacement curve; spinal instability; stiffness;
D O I
10.1097/00006123-199607000-00030
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Classically cervical biomechanical data have been obtained using cadaver models. Few methods exist for in vivo measurement of cervical biomechanics. A technique for intraoperative measurement of cervical motion segment stiffness (load-axial displacement) has been developed, enabling load/displacement data to be obtained during surgery at the spinal levels operated on and at adjacent cervical levels. METHODS: The instrument used for measuring motion segment stiffness was a vertebral retractor equipped with displacement and strain transducers and designed to be placed over the shafts of Caspar distraction screws. Stiffness was measured under simulated anterior cervical surgical conditions. RESULTS: A preliminary study deciphering axial cervical spine load/displacement data on 12 cadavers was performed with this instrument. Using a distraction load of 88.8640 N, axial displacements of 2.110 +/- 0.258 mm (mean +/- standard error of the mean) at C3-C4, 2.367 +/- 0.304 mm at C4-C5, and 2.207 +/- 0.238 mm at C5-C6 were found. When data were evaluated for age, there was a significant decrease in stiffness with advancing age in two of the three spinal segments tested (P < 0.05 for C3-C4, P < 0.04 for C4-C5, P < 0.12 for C5-C6), which correlated with previous studies. CONCLUSION: These results suggest that this technique may be useful in assessing intraoperative motion-segment stability.
引用
收藏
页码:147 / 150
页数:4
相关论文
共 18 条
[1]  
DENIS F, 1984, CLIN ORTHOP RELAT R, P65
[2]  
Ebara S, 1992, SPINE, V17, P44
[3]   DEGENERATIVE SPONDYLOLISTHESIS - TO FUSE OR NOT TO FUSE [J].
FEFFER, HL ;
WIESEL, SW ;
CUCKLER, JM ;
ROTHMAN, RH .
SPINE, 1985, 10 (03) :287-289
[4]   SEGMENTAL INSTABILITY - RATIONALE FOR TREATMENT [J].
FRYMOYER, JW ;
SELBY, DK .
SPINE, 1985, 10 (03) :280-286
[5]  
HAYASHI H, 1987, CLIN ORTHOP RELAT R, V214, P200
[6]  
MORE J, 1994, MT SINAI J MED, V61, P257
[7]   CYCLIC AXIAL LOADING OF SPINAL IMPLANTS [J].
NASCA, RJ ;
HOLLIS, JM ;
LEMONS, JE ;
COOL, TA .
SPINE, 1985, 10 (09) :792-798
[8]  
OSHEA JF, 1994, MT SINAI J MED, V61, P248
[9]   A TECHNIQUE FOR MEASUREMENT AND DESCRIPTION OF 3-DIMENSIONAL 6-DEGREE-OF-FREEDOM MOTION OF A BODY JOINT WITH AN APPLICATION TO THE HUMAN SPINE [J].
PANJABI, MM ;
KRAG, MH ;
GOEL, VK .
JOURNAL OF BIOMECHANICS, 1981, 14 (07) :447-+
[10]   EFFECTS OF DISK INJURY ON MECHANICAL-BEHAVIOR OF THE HUMAN SPINE [J].
PANJABI, MM ;
KRAG, MH ;
CHUNG, TQ .
SPINE, 1984, 9 (07) :707-713