Magnetic Bead-Based Reverse Colorimetric Immunoassay Strategy for Sensing Biomolecules

被引:216
作者
Gao, Zhuangqiang [1 ]
Xu, Mingdi [1 ]
Hou, Li [1 ]
Chen, Guonan [1 ]
Tang, Dianping [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fujian Prov & Minist Educ China, Key Lab Anal & Detect Food Safety, Fuzhou 350108, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
MULTIPLEXED ELECTROCHEMICAL IMMUNOASSAY; GOLD NANOPARTICLES; ULTRASENSITIVE DETECTION; SIGNAL AMPLIFICATION; BIOMARKERS; CATALASE; ELISA; ASSAY; NANOMATERIALS; NANOSENSORS;
D O I
10.1021/ac401433p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel reverse colorimetric immunoassay (RCIA) strategy was for the first time designed and utilized for sensitive detection of low-abundance protein (prostate-specific antigen, PSA, used in this case) in biological fluids by coupling highly catalytic efficient catalase with magnetic bead-based peroxidase mimics. To construct such a RCIA system, two nanostructures including magnetic beads and gold nanoparticles were first synthesized and functionalized with anti-PSA capture antibody and catalase/anti-PSA detection antibody, respectively. Thereafter, a specific sandwich-type immunoassay format was employed for determination of PSA by using functional gold nanopartides as enzymatic bioreactors and anti-PSA-conjugated magnetic beads as a calorimetric developer. The carried catalase, followed by the sandwiched immunocomplex, partially consumed the added hydrogen peroxide in the detection solution, which slowed down the catalytic efficiency of magnetic bead-based peroxidase mimics toward TMB/H2O2, thereby weakening the visible color and decreasing the colorimetric density. Different from conventional calorimetric immunoassay, the RCIA method determined the residual hydrogen peroxide in the substrate after consumption. Under the optimal conditions, the developed RC1A exhibited a wide dynamic range of 0.05-20 ng mL(-1) toward PSA with a detection limit of 0.03 ng mL(-1) at the 3S(blank) level. Infra- and interassay coefficients of variation were below 6.1% and 9.3%, respectively. Additionally, the methodology was further validated for the analysis of 12 PSA clinical serum specimens, giving results in good accordance with those obtained by the commercially available enzyme-linked immunosorbent assay (ELISA) method.
引用
收藏
页码:6945 / 6952
页数:8
相关论文
共 36 条
[1]   Enhanced Gold Nanoparticle Based ELISA for a Breast Cancer Biomarker [J].
Ambrosi, Adriano ;
Airo, Federico ;
Merkoci, Arben .
ANALYTICAL CHEMISTRY, 2010, 82 (03) :1151-1156
[2]  
Ammnam M., 2011, SENSOR ACTUAT B-CHEM, V160, P1063
[3]  
[Anonymous], 2011, Angew. Chem., DOI DOI 10.1002/ANGE.201006025
[4]   Nanomaterials for Sensing and Destroying Pesticides [J].
Aragay, Gemma ;
Pino, Flavio ;
Merkoci, Arben .
CHEMICAL REVIEWS, 2012, 112 (10) :5317-5338
[5]   Catalase-coupled gold nanoparticles: Comparison between the carbodiimide and biotin-streptavidin methods [J].
Chirra, Hariharasudhan D. ;
Sexton, Travis ;
Biswal, Dipti ;
Hersh, Louis B. ;
Hilt, J. Zach .
ACTA BIOMATERIALIA, 2011, 7 (07) :2865-2872
[6]   Spherical Nucleic Acids [J].
Cutler, Joshua I. ;
Auyeung, Evelyn ;
Mirkin, Chad A. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (03) :1376-1391
[7]  
de la Rica R, 2012, NAT NANOTECHNOL, V7, P821, DOI [10.1038/nnano.2012.186, 10.1038/NNANO.2012.186]
[8]  
Deshpande SS., 1996, ENZYME IMMUNOASSAYS
[9]   ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA) QUANTITATIVE ASSAY OF IMMUNOGLOBULIN-G [J].
ENGVALL, E ;
PERLMANN, P .
IMMUNOCHEMISTRY, 1971, 8 (09) :871-&
[10]   Intrinsic peroxidase-like activity of ferromagnetic nanoparticles [J].
Gao, Lizeng ;
Zhuang, Jie ;
Nie, Leng ;
Zhang, Jinbin ;
Zhang, Yu ;
Gu, Ning ;
Wang, Taihong ;
Feng, Jing ;
Yang, Dongling ;
Perrett, Sarah ;
Yan, Xiyun .
NATURE NANOTECHNOLOGY, 2007, 2 (09) :577-583