Fast detection of venous air embolism in Doppler heart sound using the wavelet transform

被引:35
作者
Chan, BCB
Chan, FHY
Lam, FK
Lui, PW
Poon, PWF
机构
[1] UNIV HONG KONG,DEPT ELECT & ELECT ENGN,HONG KONG,HONG KONG
[2] VET GEN HOSP,DEPT ANESTHESIOL,TAIPEI,TAIWAN
[3] NATL CHENG KUNG UNIV,SCH MED,DEPT PHYSIOL,TAINAN 70101,TAIWAN
关键词
precordial Doppler ultrasound; venous air embolism; wavelet transform;
D O I
10.1109/10.563293
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The introduction of air bubbles into the systemic circulation can result in significant morbidity, Real-time monitoring of continuous heart sound in patients detected by precordial Doppler ultrasound is, thus, vital for early detection of venous air embolism (VAE) during surgery, In this study, the multiscale feature of wavelet transforms (WT's) is exploited to examine the embolic Doppler heart sound (DHS) during intravenous air injections in dogs, As both humans and dogs share similar physiological conditions, our methods and results for dogs are expected to be applicable to humans, The WT of DHS at scale 2(j)(j = 1:2) selectively magnified the power of embolic, but not the normal, heart sound. Statistically, the enhanced embolic power was found to be sensitive (P < 0.01 at 0.01 mi of injected air) and correlated significantly (P < 0.0005, r = 0.83) with the volume of injected air from 0.01 to 0.10 mi, A fast detection algorithm of O(N) complexity with unit complexity constant for VAE was developed (processing speed = 8 ms per heartbeat), which confirmed the feasibility of real-time processing for both humans and dogs.
引用
收藏
页码:237 / 246
页数:10
相关论文
共 14 条
[1]  
ALDER HL, 1972, INTRO PROBABILITY ST, P153
[2]  
[Anonymous], 1993, Ten Lectures of Wavelets
[3]  
CHAN BCB, 1995, ENG PHYSICS MED C PR, P185
[4]   AIR-EMBOLISM IN UPRIGHT NEUROSURGICAL PATIENTS - DETECTION AND LOCALIZATION BY TWO-DIMENSIONAL TRANS-ESOPHAGEAL ECHOCARDIOGRAPHY [J].
CUCCHIARA, RF ;
NUGENT, M ;
SEWARD, JB ;
MESSICK, JM .
ANESTHESIOLOGY, 1984, 60 (04) :353-355
[5]   COMPARISON OF VENOUS AIR-EMBOLISM MONITORING METHODS IN SUPINE DOGS [J].
ENGLISH, JB ;
WESTENSKOW, D ;
HODGES, MR ;
STANLEY, TH .
ANESTHESIOLOGY, 1978, 48 (06) :425-429
[6]   SPECTRAL CHARACTERISTICS OF EMBOLIC HEART SOUNDS DETECTED BY PRECORDIAL DOPPLER ULTRASOUND DURING VENOUS AIR-EMBOLISM IN DOGS [J].
LUI, PW ;
LIN, YM ;
CHAN, FHY ;
TSOU, MY ;
WANG, S ;
LAM, FK ;
POON, PWF .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (05) :689-695
[7]   PRECORDIAL ULTRASONIC MONITORING DURING CESAREAN DELIVERY [J].
MALINOW, AM ;
NAULTY, JS ;
HUNT, CO ;
DATTA, S ;
OSTHEIMER, GW .
ANESTHESIOLOGY, 1987, 66 (06) :816-819
[8]   CHARACTERIZATION OF SIGNALS FROM MULTISCALE EDGES [J].
MALLAT, S ;
ZHONG, S .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (07) :710-732
[9]  
Meyer Y., 2004, WAVELETS OPERATORS
[10]   EVALUATION OF AN ULTRASONIC DEVICE (DOPPLER) FOR DIAGNOSIS OF VENOUS AIR EMBOLISM [J].
MICHENFELDER, JD ;
MILLER, RH ;
GRONERT, GA .
ANESTHESIOLOGY, 1972, 36 (02) :164-+