Recent developments in integrated circuit calorimetry

被引:54
作者
Lerchner, J [1 ]
Wolf, A [1 ]
Wolf, G [1 ]
机构
[1] Tech Univ Freiberg, Bergakad Freiberg, Inst Phys Chem, D-09596 Freiberg, Germany
来源
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY | 1999年 / 57卷 / 01期
关键词
enzyme catalised reactions; inhibitors; integrated thermopiles; micro calorimeter;
D O I
10.1023/A:1010152517237
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present paper the properties of a new class of calorimeters, so called integrated circuit calorimeters (IC calorimeters) are discussed. IC calorimeters are constructed on the basis of micro-sized silicon chips with integrated thermopile and heater. The applicability of integrated circuits for calorimetric purposes strongly depends on their sensitivity and on an optimized area of the sensitive sphere. Thus the sensitivity has to be much higher than that of the heat power transducers of conventional calorimeters. The parameters of different integrated circuits are compared corresponding to their use in calorimeters. Different constructions of IC calorimeters are possible: batch and flow-through calorimeters operating at isoperibol or temperature scanning mode. As an example a batch type IC calorimeter for liquid samples with a resolution in heat measurement of <100 mu J is described in more detail. The applications of this calorimeter are represented in the paper with the investigation of enzyme catalysed reactions, i.e. the hydrolysis of urea and the oxidation of glucose catalysed by the enzymes glucose oxidase and catalase.
引用
收藏
页码:241 / 251
页数:11
相关论文
共 12 条
[1]  
[Anonymous], 1986, SENSORS ACTUATORS, DOI DOI 10.1016/0250-6874(86)80053-1
[2]   AN INTEGRATED SILICON THERMOPILE AS BIOSENSOR FOR THE THERMAL MONITORING OF GLUCOSE, UREA AND PENICILLIN [J].
BATAILLARD, P ;
STEFFGEN, E ;
HAEMMERLI, S ;
MANZ, A ;
WIDMER, HM .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (02) :89-98
[3]   A CALORIMETRIC DETERMINATION OF ENTHALPY OF IONIZATION OF WATER AND ENTHALPY OF PROTONATION OF THAM AT 5,20,25,35, AND 50 DEGREES C [J].
GRENTHE, I ;
OTS, H ;
GINSTRUP, O .
ACTA CHEMICA SCANDINAVICA, 1970, 24 (03) :1067-&
[4]  
Hohne G., 1996, DIFFERENTIAL SCANNIN
[5]   THERMOELECTRICAL MICRO-CALORIMETRY AND MICROANALYSIS ON FREESTANDING MEMBRANES [J].
KOHLER, JM ;
KESSLER, E ;
STEINHAGE, G ;
GRUNDIG, B ;
CAMMANN, K .
MIKROCHIMICA ACTA, 1995, 120 (1-4) :309-319
[6]   Chip reactor for microfluid calorimetry [J].
Kohler, JM ;
Zieren, M .
THERMOCHIMICA ACTA, 1998, 310 (1-2) :25-35
[7]   Ambient perturbation reduction in microsized calorimetric systems [J].
Lerchner, J ;
Wolf, G ;
Torralba, A ;
Torra, V .
THERMOCHIMICA ACTA, 1997, 302 (1-2) :201-210
[8]   Supermicrocalorimetric devices for the investigation of small samples [J].
Lerchner, J ;
Oehmgen, R ;
Wolf, G ;
Le Parlouer, P ;
Daudon, JL .
HIGH TEMPERATURES-HIGH PRESSURES, 1998, 30 (06) :701-708
[9]  
LERCHNER J, IN PRESS THERMOCHIM
[10]  
LERCHNER J, 1997, MICROREACTION TECHNO, P316