Indications for TEE Before Cardioversion for Atrial Fibrillation: Implications for Appropriateness Criteria

被引:10
作者
Grewal, Gaganpreet K.
Klosterman, Tristan B.
Shrestha, Kevin
Yarmohammadi, Hirad
Zurick, Andrew O.
Varr, Brandon C. [2 ]
Tang, W. H. Wilson
Lindsay, Bruce D.
Klein, Allan L. [1 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Inst Heart & Vasc, Cleveland, OH 44195 USA
[2] Stanford Hosp & Clin, Dept Med, Stanford, CA USA
关键词
atrial fibrillation; cardioversion; transesophageal echocardiography; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; THROMBI;
D O I
10.1016/j.jcmg.2011.12.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate appropriateness of transesophageal echocardiography (TEE) before direct current cardioversion (DCC), investigate indications for TEE, and analyze if indications are predictive of outcome. According to American College of Cardiology Foundation/American Society of Echocardiography 2011 Appropriateness Criteria, TEE is appropriate in the evaluation of patients with atrial fibrillation (AF) to facilitate clinical decision making with regards to anticoagulation and/or DCC. However, it is unclear in which instances physicians utilize TEE. We reviewed 671 TEE studies in 604 AF patients (age 66 +/- 13 years, 67% male) in which TEE was performed before DCC for left atrial thrombus (LAT)/sludge. Studies were divided by the main indication for TEE into the following 8 categories: 1) congestive heart failure (CHF)/hemodynamic compromise; 2) symptomatic; 3) new onset AF; 4) hospitalized and symptomatic; 5) high stroke risk; 6) subtherapeutic anticoagulation; 7) miscellaneous; and 8) inappropriate for TEE. The main indications for TEE before DCC were symptomatic (26.4%) and CHF/hemodynamic compromise (26.1%). We deemed 2.7% of the studies as inappropriate. LAT/sludge was found in 8.2% of studies. Incidence of LAT/sludge differed significantly between indications (p = 0.0021) and the highest incidences occurred in the high stroke risk (17.6%) and hospitalized and symptomatic (14.1%) categories. No LAT/sludge was found in the miscellaneous or inappropriate groups. Stroke occurred in 2.5% (n = 15) of all patients and in all groups except for miscellaneous and inappropriate (p = 0.3). TEE is appropriately used prior to DCC for patients with the main indications of symptomatic and CHF/hemodynamic compromise. In a minority of studies, TEE utilization was inappropriate. Incidence of LAT/sludge differed between indications.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 15 条
[1]  
[Anonymous], 2006, J AM COLL CARDIOL
[2]   Transesophageal echocardiography to guide electrical cardioversion in atrial fibrillation [J].
Asher, CR ;
Klein, AL .
CLEVELAND CLINIC JOURNAL OF MEDICINE, 2002, 69 (09) :713-718
[3]   ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography [J].
Douglas, Pamela S. ;
Garcia, Mario J. ;
Haines, David E. ;
Lai, Wyman W. ;
Manning, Warren J. ;
Patel, Ayan R. ;
Picard, Michael H. ;
Polk, Donna M. ;
Ragosta, Michael ;
Ward, R. Parker ;
Weiner, Rory B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (09) :1126-1166
[4]   Impact of cardioversion strategy on functional capacity in patients with atrial fibrillation: The Assessment of Cardioversion Using Transesophageal Echocardiography (ACUTE) Study [J].
Jasper, SE ;
Lieber, EA ;
Murray, RD ;
Apperson-Hansen, C ;
Black, IW ;
Grimm, RA ;
Pape, LA ;
Klein, AL .
AMERICAN HEART JOURNAL, 2005, 149 (02) :309-315
[5]   Prevalence of Left Atrial Thrombus and Dense Spontaneous Echo Contrast in Patients With Short-Term Atrial Fibrillation < 48 Hours Undergoing Cardioversion: Value of Transesophageal Echocardiography to Guide Cardioversion [J].
Kleemann, Thomas ;
Becker, Torsten ;
Strauss, Margit ;
Schneider, Steffen ;
Seidl, Karlheinz .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (12) :1403-1408
[6]   Efficacy of transesophageal echocardiography-guided cardioversion of patients with atrial fibrillation at 6 months: A randomized controlled trial [J].
Klein, AL ;
Grimm, RA ;
Jasper, SE ;
Murray, RD ;
Apperson-Hansen, C ;
Lieber, EA ;
Black, IW ;
Davidoff, R ;
Erbel, R ;
Halperin, JL ;
Orsinelli, DA ;
Porter, TR ;
Stoddard, MF .
AMERICAN HEART JOURNAL, 2006, 151 (02) :380-389
[7]   Use of transesophageal echocardiography to guide cardioversion in patients with atrial fibrillation. [J].
Klein, AL ;
Grimm, RA ;
Murray, RD ;
Apperson-Hansen, C ;
Asinger, RW ;
Black, IW ;
Davidoff, R ;
Erbel, R ;
Halperin, JL ;
Orsinelli, DA ;
Porter, TR ;
Stoddard, MF .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (19) :1411-1420
[8]   Evaluation of the Application of the ACCF/ASE Appropriateness Criteria for Transesophageal Echocardiography in an Academic Medical Center [J].
Mansour, Ibrahim N. ;
Lang, Roberto M. ;
Furlong, Kathy T. ;
Ryan, Anne ;
Ward, R. Parker .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (05) :517-522
[9]   National use of the transesophageal echocardiographic-guided approach to cardioversion for patients in atrial fibrillation [J].
Murray, RD ;
Goodman, AS ;
Lieber, EA ;
Jasper, SE ;
Grimm, RA ;
Garcia, MJ ;
Miller, DM ;
Klein, AL .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (02) :239-244
[10]   Dabigatran Versus Warfarin in Patients With Atrial Fibrillation An Analysis of Patients Undergoing Cardioversion [J].
Nagarakanti, Rangadham ;
Ezekowitz, Michael D. ;
Oldgren, Jonas ;
Yang, Sean ;
Chernick, Michael ;
Aikens, Timothy H. ;
Flaker, Greg ;
Brugada, Josep ;
Kamensky, Gabriel ;
Parekh, Amit ;
Reilly, Paul A. ;
Yusuf, Salim ;
Connolly, Stuart J. .
CIRCULATION, 2011, 123 (02) :131-136