Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis

被引:38
作者
Bizet, K
Gabrielli, C
Perrot, H
Therasse, J
机构
[1] Univ Paris 06, UPR 15 CNRS Phys Liquides & Electrochim, F-75252 Paris 05, France
[2] Ctr Etud Bouchet, Biotechnol Lab, F-91710 Vert Le Petit, France
关键词
QCM; immunosensors; electroacoustic admittance; enzymes adsorption;
D O I
10.1016/S0956-5663(97)00139-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of immunosensors based on piezoelectric transducers is widely investigated due to their attractive potentialities. The quartz crystal microbalance (QCM) may give a direct response signal which characterizes the binding event between a sensitive layer, immobilized onto the surface transducer, and the analyte to be detected. However, for small biomolecules, such as some antigens, it is quite difficult to obtain an observable signal. This is mainly due to the lack of sensitivity of the commonly used QCM (5 to 10 MHz quartz crystal). Moreover, the mass estimated with the QCM response through the Sauerbrey equation and the mass which can be measured thanks to other analytical techniques, in our case an enzymatic assay, are different: the deposited mass is generally overestimated by the QCM. To validate QCM mass measurements and, therefore antigens recognition, the interactions of acoustic shear waves with a biolayer were investigated during enzyme adsorption onto the microbalance gold electrode or during the antibody/antigen binding. Electroacoustic admittance was measured around the resonance frequency of a 27 MHz quartz resonator in parallel with microbalance measurements. The parameters which characterize the quartz microbalance equivalent circuit were compared with the classical microbalance frequency. The mass overestimation, given by the microbalance, could be explained either by modification of the rheological properties of the sensitive layers and/or by an inadequacy of the assay performed. (C) 1998 Elsevier Science S.A.
引用
收藏
页码:259 / 269
页数:11
相关论文
共 13 条
[1]   QUARTZ-CRYSTAL MICROBALANCE SENSOR IN LIQUIDS [J].
AUGE, J ;
HAUPTMANN, P ;
EICHELBAUM, F ;
ROSLER, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) :518-522
[2]   STUDY OF IMMUNOGLOBULIN-G THIN-LAYERS OBTAINED BY THE LANGMUIR-BLODGETT METHOD - APPLICATION TO IMMUNOSENSORS [J].
BARRAUD, A ;
PERROT, H ;
BILLARD, V ;
MARTELET, C ;
THERASSE, J .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (01) :39-48
[3]  
BIZET K, IN PRESS
[4]   CALIBRATION OF THE ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE [J].
GABRIELLI, C ;
KEDDAM, M ;
TORRESI, R .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (09) :2657-2660
[5]   PIEZOELECTRIC CRYSTAL FOR THE DETECTION OF IMMUNOREACTIONS IN BUFFER SOLUTIONS [J].
GEDDES, NJ ;
PASCHINGER, EM ;
FURLONG, DN ;
EBARA, Y ;
OKAHATA, Y ;
THAN, KA ;
EDGAR, JA .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 17 (02) :125-131
[6]   CHARACTERIZATION OF A THICKNESS-SHEAR MODE QUARTZ RESONATOR WITH MULTIPLE NONPIEZOELECTRIC LAYERS [J].
GRANSTAFF, VE ;
MARTIN, SJ .
JOURNAL OF APPLIED PHYSICS, 1994, 75 (03) :1319-1329
[7]  
MATTHYS RJ, 1983, CRYSTAL OSCILLATOR C
[8]   QUARTZ-CRYSTAL MICROBALANCE FOR THE DETECTION OF MICROGRAM QUANTITIES OF HUMAN SERUM-ALBUMIN - RELATIONSHIP BETWEEN THE FREQUENCY CHANGE AND THE MASS OF PROTEIN ADSORBED [J].
MURATSUGU, M ;
OHTA, F ;
MIYA, Y ;
HOSOKAWA, T ;
KUROSAWA, S ;
KAMO, N ;
IKEDA, H .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2933-2937
[9]   INTEGRATED OPTICAL INPUT GRATING COUPLERS AS BIOCHEMICAL SENSORS [J].
NELLEN, PM ;
TIEFENTHALER, K ;
LUKOSZ, W .
SENSORS AND ACTUATORS, 1988, 15 (03) :285-295
[10]   QCM operation in liquids: Constant sensitivity during formation of extended protein multilayers by affinity [J].
Rickert, J ;
Brecht, A ;
Gopal, W .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1441-1448