Effect of the flow rate on the measurement of adsorption data by dynamic frontal analysis

被引:26
作者
Gritti, F
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
adsorption isotherm; frontal analysis method; calculation of elution profiles method; flow rate; liquid chromatography; propylbenzoate; column efficiency;
D O I
10.1016/j.chroma.2004.08.129
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The adsorption data of propyl benzoate were acquired by frontal analysis (FA) on a Symmetry-C-18 column, using a mixture of methanol (65%, v/v) and water as the mobile phase, at three different flow rates, 0.5, 1.0 and 2.0 mL/min. The exact flow rates F, were measured by collecting the mobile phase in volumetric glasses (delta F-v/F-v <= 0.2%). The extra-column volumes and the column hold-up volume were accurately measured at each flow rate by tracer injections. The detailed effect of the flow rate on the value of the amount adsorbed was investigated. The best isotherm model accounting for the adsorption data was the same BET isotherm model at all three flow rates. Only slight differences (always less than 5%) were found between the three different sets of isotherm parameters (saturation capacity, q(s), equilibrium constant on the adsorbent, b(s) and equilibrium constant on successive layers of propyl benzoate, b(L)). The reproducibility of the same isotherm parameters measured by the inverse method (IM) is less satisfactory, leading to R.S.D.s of up to 10%. A flow rate increase is systematically accompanied by a slight increase of the amount adsorbed. This phenomenon is consistent with the influence of the pressure on the equilibrium constant of adsorption due to the difference between the partial molar volumes of the solute and the adsorbate. The larger average pressure along the column that is required to achieve a larger flow rate causes a larger amount of solute to be adsorbed on the column at equilibrium. This result comforts the high sensitivity and versatility of the FA method for isotherm determination under any kind of situation. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 42
页数:12
相关论文
共 32 条
[1]   MESSUNG VON ADSORPTIONSISOTHERMEN AN KATALYSATOREN BEI HOHEN TEMPERATUREN MIT HILFE DER GAS-FESTKORPER-ELUIERUNGSCHROMATOGRAPHIE [J].
CREMER, E ;
HUBER, H .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1961, 73 (13) :461-&
[2]   CONTINUOUS FLOW SYSTEMS - DISTRIBUTION OF RESIDENCE TIMES [J].
DANCKWERTS, PV .
CHEMICAL ENGINEERING SCIENCE, 1953, 2 (01) :1-13
[3]   CALIBRATING DETECTOR RESPONSES USING CHROMATOGRAPHIC PEAK SHAPES [J].
DOSE, EV ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :816-820
[4]   DETERMINATION OF ISOTHERMS FROM CHROMATOGRAPHIC PEAK SHAPES [J].
DOSE, EV ;
JACOBSON, S ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :833-839
[5]   Numerical determination of the competitive isotherm of enantiomers [J].
Felinger, A ;
Cavazzini, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) :207-225
[6]   Adsorption isotherms of nonionic surfactants in SBA-15 measured by micro-column chromatography [J].
Findenegg, G. H. ;
Eltekov, A. Y. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) :236-240
[7]   THEORY OF CHROMATOGRAPHY .10. FORMULAE FOR DIFFUSION INTO SPHERES AND THEIR APPLICATION TO CHROMATOGRAPHY [J].
GLUECKAUF, E .
TRANSACTIONS OF THE FARADAY SOCIETY, 1955, 51 (11) :1540-1551
[8]   Adsorption isotherms of the fullerenes C60 and C70 on a tetraphenylporphyrin-bonded silica [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1053 (1-2) :59-69
[9]   Accuracy and precision of adsorption isotherm parameters measured by dynamic HPLC methods [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1043 (02) :159-170
[10]   Heterogeneity of the surface energy on unused C18-chromolith adsorbents in reversed-phase liquid chromatography [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (01) :105-119