Dose reduction in evacuation proctography

被引:6
作者
Hare, C [1 ]
Halligan, S [1 ]
Bartram, CI [1 ]
Gupta, R [1 ]
Walker, AE [1 ]
Renfrew, I [1 ]
机构
[1] St Marks Hosp, Intestinal Imaging Ctr, Harrow HA1 3UJ, Middx, England
关键词
defecography; dosimetry; rectum radiography; digital radiography;
D O I
10.1007/s003300000613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The goal of this study was to reduce the patient radiation dose from evacuation proctography. Ninety-eight consecutive adult patients referred for proctography to investigate difficult rectal evacuation were studied using a digital imaging system with either a standard digital program for barium examinations, a reduced dose digital program (both with and without additional copper filtration), or Video fluoroscopy. Dose-area products were recorded for each examination and the groups were compared. All four protocols produced technically acceptable examinations. The low-dose program with copper filtration (median dose 382 cGy cm(2)) and Video fluoroscopy (median dose 705 cGy cm(2)) were associated with significantly less dose than other groups (p < 0.0001). Patient dose during evacuation proctography can be reduced significantly without compromising the diagnostic quality of the examination. A digital program with added copper filtration conveyed the lowest dose.
引用
收藏
页码:432 / 434
页数:3
相关论文
共 11 条
[1]
EVACUATION PROCTOGRAPHY - AN INVESTIGATION OF RECTAL EXPULSION IN 20 SUBJECTS WITHOUT DEFECATORY DISTURBANCE [J].
BARTRAM, CI ;
TURNBULL, GK ;
LENNARDJONES, JE .
GASTROINTESTINAL RADIOLOGY, 1988, 13 (01) :72-80
[2]
THE IMPACT OF DIGITAL IMAGING ON PATIENT DOSES DURING BARIUM STUDIES [J].
BROADHEAD, DA ;
CHAPPLE, CL ;
FAULKNER, K .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (813) :992-996
[3]
RADIATION-DOSE IN DEFECOGRAPHY [J].
GOEI, R ;
KEMERINK, G .
RADIOLOGY, 1990, 176 (01) :137-139
[4]
PROCTOGRAPHIC FEATURES OF ANISMUS [J].
HALLIGAN, S ;
BARTRAM, CI ;
PARK, HJ ;
KAMM, MA .
RADIOLOGY, 1995, 197 (03) :679-682
[5]
Added copper filtration in digital paediatric double-contrast colon examinations: effects on radiation dose and image quality [J].
Hansson, B ;
Finnbogason, T ;
Schuwert, P ;
Persliden, J .
EUROPEAN RADIOLOGY, 1997, 7 (07) :1117-1122
[6]
Evacuation proctography: A prospective study of diagnostic and therapeutic effects [J].
Harvey, CJ ;
Halligan, S ;
Bartram, CI ;
Hollings, N ;
Sahdev, A ;
Kingston, K .
RADIOLOGY, 1999, 211 (01) :223-227
[7]
OUTCOME OF COLECTOMY FOR SEVERE IDIOPATHIC CONSTIPATION [J].
KAMM, MA ;
HAWLEY, PR ;
LENNARDJONES, JE .
GUT, 1988, 29 (07) :969-973
[8]
PELVIC PROLAPSE - ASSESSMENT WITH EVACUATION PROCTOGRAPHY (DEFECOGRAPHY) [J].
KELVIN, FM ;
MAGLINTE, DDT ;
HORNBACK, JA ;
BENSON, JT .
RADIOLOGY, 1992, 184 (02) :547-551
[9]
DEFECOGRAPHY .1. DESCRIPTION OF A NEW PROCEDURE AND RESULTS IN NORMAL-PATIENTS [J].
MAHIEU, P ;
PRINGOT, J ;
BODART, P .
GASTROINTESTINAL RADIOLOGY, 1984, 9 (03) :247-251
[10]
MCGEE SG, 1993, ABDOM IMAGING, V18, P136