MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence

被引:37
作者
Chang, SD
Lee, MJ
Munk, PL
Janzen, DL
MacKay, A
Xiang, QS
机构
[1] Vancouver Gen Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Phys, Vancouver, BC, Canada
[3] St Pauls Hosp, Dept Radiol, Vancouver, BC V6Z 1Y6, Canada
[4] British Columbia Childrens Hosp, Vancouver, BC V6H 3V4, Canada
关键词
magnetic resonance imaging; artifact; metal implants and hardware; spine; view angle tilting; MARS (metal artifact reduction sequence);
D O I
10.1007/s002560100331
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. This study was designed to compare diagnostic quality of MR images of patients with spinal hardware acquired using a conventional T1-weighted spin-echo sequence and a new metal artifact reduction sequence (MARS). Conclusion. The new MARS sequence effectively reduces the degree of tissue-obscuring artifact produced by spinal fixation hardware and subjectively improves image quality compared with the conventional T1-weighted spin-echo sequence.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 14 条
[1]
MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[2]
CHANG SD, 1998, RADIOLOGY, V209, P614
[3]
TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[4]
CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149
[5]
THE EFFECT OF METALLIC IMPLANTS ON MAGNETIC-RESONANCE-IMAGING - A BRIEF NOTE [J].
EBRAHEIM, NA ;
COOMBS, RE ;
JACKSON, WT ;
ZEISS, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (09) :1397-1398
[6]
MR imaging of soft tissues adjacent to orthopaedic hardware: Techniques to minimize susceptibility artefact [J].
Eustace, S ;
Goldberg, R ;
Williamson, D ;
Melhem, ER ;
Oladipo, O ;
Yucel, EK ;
Jara, H .
CLINICAL RADIOLOGY, 1997, 52 (08) :589-594
[7]
EFFECT OF FIELD-STRENGTH ON SUSCEPTIBILITY ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING [J].
FARAHANI, K ;
SINHA, U ;
SINHA, S ;
CHIU, LCL ;
LUFKIN, RB .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (06) :409-413
[8]
ARTIFACTS IN MR IMAGING AFTER SURGICAL INTERVENTION [J].
HEINDEL, W ;
FRIEDMANN, G ;
BUNKE, J ;
THOMAS, B ;
FIRSCHING, R ;
ERNESTUS, RI .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (04) :596-599
[9]
MR IMAGING IN PATIENTS WITH METALLIC IMPLANTS [J].
LAAKMAN, RW ;
KAUFMAN, B ;
HAN, JS ;
NELSON, AD ;
CLAMPITT, M ;
OBLOCK, AM ;
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1985, 157 (03) :711-714
[10]
MCGOWAN AJ, 1997, P INT SOC MAGN RES M, P3